Proceedings of the 2005 IEEE International Frequency Control Symposium and Exposition, 2005.
DOI: 10.1109/freq.2005.1573955
|View full text |Cite
|
Sign up to set email alerts
|

Experimental assessment of the time transfer capability of precise point positioning (PPP)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
31
0

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 44 publications
(35 citation statements)
references
References 9 publications
0
31
0
Order By: Relevance
“…The coefficient ε ≥ 0 quantifies the fidelity F, and ε 0 ≥ 0 quantifies the fidelity F 0 . The coefficients can be considered as defining the response of a filter with transfer functions T( f ) and T 0 ( f ), respectively, where T( f ) = 1/(1 + (1/ε)(2π f ) 6 ) and T 0 ( f ) = 1/(1 + (1/ε 0 )(2π f ) 4 ). The dimensions of ε and ε 0 are time −6 and time −4 , respectively.…”
Section: Combination Of Ppp With Two-way Time Transfermentioning
confidence: 99%
See 2 more Smart Citations
“…The coefficient ε ≥ 0 quantifies the fidelity F, and ε 0 ≥ 0 quantifies the fidelity F 0 . The coefficients can be considered as defining the response of a filter with transfer functions T( f ) and T 0 ( f ), respectively, where T( f ) = 1/(1 + (1/ε)(2π f ) 6 ) and T 0 ( f ) = 1/(1 + (1/ε 0 )(2π f ) 4 ). The dimensions of ε and ε 0 are time −6 and time −4 , respectively.…”
Section: Combination Of Ppp With Two-way Time Transfermentioning
confidence: 99%
“…This is possible thanks to the precise satellite orbits and clocks provided by the International GNSS Service (IGS) [2], where the reference time scale is IGS time [3]. In recent years, the time community has shown a growing interest in this technique and a number of time transfer experiments have been carried out (see, e.g., [4][5][6]). …”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Measurements were performed over a two month period with data collected relative to the maser frequency. The maser is calibrated in its absolute offset from the SI second through international GPS satellite intercomparison using the Natural Resources Canada Precise Point Positioning (PPP) data-processing technique [27] and using the Bureau International des Poids et Mesures (BIPM) circular-T reports. Using such corrections together with NRC inhouse frequency standards, it was possible to obtain uncertainties of the measured ion center frequency to a resulting final value of 0.9 Hz.…”
Section: H Y S I C a L R E V I E W L E T T E R Smentioning
confidence: 99%
“…from multi-path or temperature dependences) may has a larger effect on clock jumps between arcs. Various methods for mitigating or compensating daily jumps such as phase-only method, sliding batch solution (SBS), clock handover and so on are already presented in (Orgiazzi et al 2005, Dach et al 2006, Defraigne et al 2008. However, fully compensation method is not yet presented.…”
Section: Introductionmentioning
confidence: 99%