2015
DOI: 10.1016/j.applthermaleng.2015.05.016
|View full text |Cite
|
Sign up to set email alerts
|

Experimental and theoretical investigation on the performance of CO2/propane auto-cascade refrigerator with a fractionation heat exchanger

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
9
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 54 publications
(9 citation statements)
references
References 24 publications
0
9
0
Order By: Relevance
“…The relationship between condenser temperature and exergy efficiency is not linier, will reach a minimum value under certain conditions. The results of this research are relevant to the results of study can be seen in review papers by several authors [19,20,22], that is, if the condenser temperature rises, the exergy efficiency will decrease. In Figure 8, shows the effect of evaporator temperature on mass ratio HTC and LTC, where / has a linier trend that is inversely related to increase of evaporator temperature, the mass ratio / decrease.…”
Section: Effect Evaporator Temperature On Cop Cascadementioning
confidence: 59%
See 2 more Smart Citations
“…The relationship between condenser temperature and exergy efficiency is not linier, will reach a minimum value under certain conditions. The results of this research are relevant to the results of study can be seen in review papers by several authors [19,20,22], that is, if the condenser temperature rises, the exergy efficiency will decrease. In Figure 8, shows the effect of evaporator temperature on mass ratio HTC and LTC, where / has a linier trend that is inversely related to increase of evaporator temperature, the mass ratio / decrease.…”
Section: Effect Evaporator Temperature On Cop Cascadementioning
confidence: 59%
“…Figure 5, it shows if the evaporator temperature goes up increase from 200 K to 270 K, the total exergy loss or total energy loss decreases. While the lowest amount of energy loss is MC22-R404A, the highest total exergy loss is MC134-R404A which is 11.75 kW, when evaporator temperature 220 K. The results of this phenomenon are relevant to results research [19,[21][22]. Figure 6, it shows that effect evaporator temperature on exergy efficiency, where the relationship is not linier.…”
Section: Effect Evaporator Temperature On Cop Cascadementioning
confidence: 80%
See 1 more Smart Citation
“…Thus the assumption of the temperature approaches across the IHXs should be confirmed by a detailed temperature distribution analysis as stated by Rozhenstev [23]. Otherwise very small or even negative temperature differences at the pinch points may occur if the assumed temperature approach is relatively low in the range of 3 K to 5 K resulting in system parameters that vary from the simulated values [21].…”
mentioning
confidence: 83%
“…The calculated COP value was higher in low-temperature ambient conditions. A modified propane/CO 2 ACR system with a fractionation heat exchanger (FHEX) in the form of a rectifying column in the upper section of the phase separator was investigated by Zhang et al [21]. The FHEX improved separation efficiency, resulting in lower evaporation temperatures.…”
Section: Introductionmentioning
confidence: 99%