2018
DOI: 10.1007/s11668-018-0473-x
|View full text |Cite
|
Sign up to set email alerts
|

Experimental and Theoretical Evaluation of Rutin as Eco-Friendly Corrosion Inhibitor for Aluminum 6063 Alloy in Acidic Medium

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 15 publications
(4 citation statements)
references
References 19 publications
0
4
0
Order By: Relevance
“…The activation energy is lesser in inhibited solution (Table 4), which denotes the role of BMDP in altering the rate of electrochemical reactions, thereby reducing the rate of corrosion. The lower E a also indicates chemisorption as a dominating type of adsorption [36] and the positive value of activation enthalpy supports an endothermic mode of interaction [37,38] …”
Section: Resultsmentioning
confidence: 95%
See 1 more Smart Citation
“…The activation energy is lesser in inhibited solution (Table 4), which denotes the role of BMDP in altering the rate of electrochemical reactions, thereby reducing the rate of corrosion. The lower E a also indicates chemisorption as a dominating type of adsorption [36] and the positive value of activation enthalpy supports an endothermic mode of interaction [37,38] …”
Section: Resultsmentioning
confidence: 95%
“…The lower E a also indicates chemisorption as a dominating type of adsorption [36] and the positive value of activation enthalpy supports an endothermic mode of interaction. [37,38] Adsorption Isotherms Adsorption studies provide information about metal-inhibitor interaction. For the present work, the Langmuir adsorption isotherm (Figure 6) suited well, which was plotted using concentration (C) and adsorption constant (K ads ) (Eq.…”
Section: Effect Of Temperature On Inhibitionmentioning
confidence: 99%
“…The proportion of the semicircle in the plot and the frequency of the capacitive loop magnifies with the elevation of concentration of PQS and MQS. The magnification of the capacitive loops is an indication of the increase in the efficacy of inhibitors, an ideal paradigm of an effective corrosion inhibitor [26,27] . The percentage efficiency of electrochemical impedance ( EISη% ${{{\rm E}{\rm I}{\rm S}}_{{\rm \eta }{\rm \char37 }}}$ ) is reckoned with Eq.…”
Section: Resultsmentioning
confidence: 99%
“…The magnifica-tion of the capacitive loops is an indication of the increase in the efficacy of inhibitors, an ideal paradigm of an effective corrosion inhibitor. [26,27] The percentage efficiency of electrochemical impedance (EIS h% ) is reckoned with Eq. ( 1), where R o ct and R ct are the charge transfer resistance of the inhibitors (PQS and MQS) without and with their incorporation.…”
Section: Electrochemical Impedance Spectroscopy (Eis)mentioning
confidence: 99%