2018
DOI: 10.1016/j.buildenv.2018.08.008
|View full text |Cite
|
Sign up to set email alerts
|

Experimental and simulation studies on dust loading performance of a novel electrostatic precipitator with dielectric barrier electrodes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
17
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 18 publications
(17 citation statements)
references
References 33 publications
0
17
0
Order By: Relevance
“…In the research on the plate-type microelectrostatic filter, the researchers have proved that the resistance of the plate-type microelectrostatic filters is only 14 Pa at 1.0 m/s, and the initial PM2.5 filtration efficiency can also reach 99.8%. However, after 50 days of operation, the PM2.5 filtration efficiency of a platetype micro-electrostatic filter drops to 50% [20]. This study also means that although the efficiency of a plate-type micro-electrostatic filter has reached the level of a medium-efficiency filter, its filter performance is challenging to regulate after it contains dust [14,20,38].…”
Section: Introductionmentioning
confidence: 86%
See 3 more Smart Citations
“…In the research on the plate-type microelectrostatic filter, the researchers have proved that the resistance of the plate-type microelectrostatic filters is only 14 Pa at 1.0 m/s, and the initial PM2.5 filtration efficiency can also reach 99.8%. However, after 50 days of operation, the PM2.5 filtration efficiency of a platetype micro-electrostatic filter drops to 50% [20]. This study also means that although the efficiency of a plate-type micro-electrostatic filter has reached the level of a medium-efficiency filter, its filter performance is challenging to regulate after it contains dust [14,20,38].…”
Section: Introductionmentioning
confidence: 86%
“…A micro-electrostatic filter is composed of multiple electric field channels, and the movement of particles in an electric field channel determines the performance of the filter. A single channel model is often used for simplified calculation [20] to simulate the performance of the electrostatic filter and was adopted in this research. We first used the methods commonly used in the literature [20,52] to simulate the flow field and the electrostatic field, and then establish the particle motion and charging model in the electric field channel.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Due to low pressure drop and high efficiency, air cleaners based on ESPs have also been widely applied to remove fine particles and improve indoor and outdoor air quality. 25 27 Thus, this study can be used to guide the removal of indoor and outdoor particles by joint electrostatic inertial separators.…”
Section: Introductionmentioning
confidence: 99%