2020
DOI: 10.1177/1420326x20961141
|View full text |Cite
|
Sign up to set email alerts
|

Experimental and simulated optimization study on dynamic heat discharge performance of multi-units water tank with PCM

Abstract: The water tank is most commonly a crucial energy storage device of a solar heating system. However, few existing studies have focused on the quantitative analysis of the heat discharge process of a square water tank. In this paper, a multi-units water tank with phase change material (MWT-PCM) was proposed. The dynamic heat discharge performances of the MWT-PCM and the conventional water tank both with 235.8 dm 3 were compared experimentally. A validated mathematical model was established to optimize the confi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 13 publications
(6 citation statements)
references
References 33 publications
0
4
0
Order By: Relevance
“…The water in the cold storage tank has obvious stratification accounting for the lower flowrate in the cooling pipe of the STRC. Thus, the water in the cold storage tank can be divided into several layers, which can be calculated by equation (18) 34,40 where Q tank (W) is the net heat transfer rate of the water in the cold storage tank; M tank (kg/s) is the mass flowrate through the cold storage tank; and T tank (K) is the average temperature of the cold storage tank.…”
Section: Methodsmentioning
confidence: 99%
“…The water in the cold storage tank has obvious stratification accounting for the lower flowrate in the cooling pipe of the STRC. Thus, the water in the cold storage tank can be divided into several layers, which can be calculated by equation (18) 34,40 where Q tank (W) is the net heat transfer rate of the water in the cold storage tank; M tank (kg/s) is the mass flowrate through the cold storage tank; and T tank (K) is the average temperature of the cold storage tank.…”
Section: Methodsmentioning
confidence: 99%
“…The validation of model results was conducted through visual analysis in the preceding article. To comprehensively expound the alignment between experimental and simulated results, we adopted the root mean square deviation (RMSD) and the coefficient of variation (CV) as evaluation metrics (Vogt et al, 2018;Li et al, 2020). The calculation formulas are expressed as:…”
Section: Evaluation and Validationmentioning
confidence: 99%
“…PCMs can be integrated into solar heating systems on roofs by using the existing roof construction as a thermal collector that minimizes the capital cost and introduces a latent thermal storage unit that minimizes the auxiliary energy requirement by storing excess solar energy for use in the absence of solar radiation. 73,74 Photovoltaic (PV) is another solar energy technology coupled with PCM and used in building roofs. It helps reduce the PV panel temperature, resulting in an increase in the amount of electricity produced.…”
Section: Pcm-enhanced Roofs and Ceilingsmentioning
confidence: 99%
“…PCMs can be integrated into solar heating systems on roofs by using the existing roof construction as a thermal collector that minimizes the capital cost and introduces a latent thermal storage unit that minimizes the auxiliary energy requirement by storing excess solar energy for use in the absence of solar radiation. 73,74…”
Section: Pcm-enhanced Building Componentsmentioning
confidence: 99%