2022
DOI: 10.1016/j.ijrefrig.2021.10.015
|View full text |Cite
|
Sign up to set email alerts
|

Experimental and numerical analysis of a helical coil heat exchanger for domestic refrigerator and water heating

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
9
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 21 publications
(9 citation statements)
references
References 18 publications
0
9
0
Order By: Relevance
“…In addition, the accuracy of experimental measurement usually depends on many technical aspects. Therefore, the uncertainty pertaining to the measuring tools can be estimated using the resultant uncertainty presented by the following formula [3]:…”
Section: Error and Uncertainty Analysismentioning
confidence: 99%
See 2 more Smart Citations
“…In addition, the accuracy of experimental measurement usually depends on many technical aspects. Therefore, the uncertainty pertaining to the measuring tools can be estimated using the resultant uncertainty presented by the following formula [3]:…”
Section: Error and Uncertainty Analysismentioning
confidence: 99%
“…Today, in residential and commercial buildings, the total energy consumed for heating and air conditioning are about 42 % and 40 % respectively [1,2]. According to Missaoui et al [3], energy conservation coupled with waste heat recovery from condenser coil of refrigeration machines become a promising and simple economic method compared with conventional methods in the field of water heating and seawater desalination. Due to the important heat transfer in the immersed heat exchanger of the refrigeration machines, many investigations on waste heat recovery from refrigeration machines are available in the literature.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In this new paper, we focus on the geometrical parameter effect and we have to change the pipe turns and keep constants all the other parameters. Based on our anterior study [30], we have chosen the time step size with a value equal to Δt =1 s.…”
Section: Meshmentioning
confidence: 99%
“…( 11)) on the basis of constant temperature boundary conditions were used. Missaoui et al, [48] numerically and experimentally compared normal coil with coil having variation in pitch and found out that average heat transfer coefficients of coil having variation in pitch was 16.7 % higher than normal coil. Omri et al, [49] carried out experimentation to study enhancement of thermal performance of single straight helical coil using flow of nanofluids in laminar regime.…”
Section: Introductionmentioning
confidence: 99%