2019
DOI: 10.1061/(asce)st.1943-541x.0002235
|View full text |Cite
|
Sign up to set email alerts
|

Experimental and Analytical Investigation of D-Type Self-Centering Steel Eccentrically Braced Frames with Replaceable Hysteretic Damping Devices

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
17
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 29 publications
(17 citation statements)
references
References 37 publications
0
17
0
Order By: Relevance
“…Each plate is divided into a tapered length and a rectangular tongue which is directly inserted into the slots of the holder bracket. After gap‐opening, the energy dissipation of the system is mainly provided by the flexural yielding mechanism of these plates 25 …”
Section: Description Of the System Behavior And Componentsmentioning
confidence: 99%
“…Each plate is divided into a tapered length and a rectangular tongue which is directly inserted into the slots of the holder bracket. After gap‐opening, the energy dissipation of the system is mainly provided by the flexural yielding mechanism of these plates 25 …”
Section: Description Of the System Behavior And Componentsmentioning
confidence: 99%
“…Nonetheless, even if the structure is subjected to a very large story drift and the PT cables are slacked, the authors found from the numerical simulation study that the structure would still maintain its stability because the RHD plates yielded and locked in the bracket slots (thus RHD behave like a partial moment connection), which can be very helpful to provide partial strength and stiffness to the severely damaged structure at the MCE R level earthquakes to avoid collapse. In order to enable the elastic response of the PT cables up to the drift demand at the DBE level, the minimum PT cable length, which is a function of the frame kinematics at the drift ratio limit at DBE (1.50%) and the initial post-tensioning force, should be provided as Equation (21).…”
Section: Design Of Scebf-srl Systemsmentioning
confidence: 99%
“…They reported that SCEBF buildings can be designed to have stiffness and ductility equal to the CEBFs. Tong et al 21 presented experimental, analytical, and numerical studies on the D-type SCEBF with replaceable hysteretic damping (RHD) devices. In such systems, the "beam growth" phenomenon is observed due to gap-opening at the end of rocking links beams.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…It was validated that SCEBF systems could be designed to possess strength and stiffness comparable to traditional steel EBFs while preserving plumbness subjected to DBE. Tong et al [104] experimentally and analytically investigated the D-type SCEBF with replaceable hysteretic damping (RHD) devices.…”
Section: Advances In Civil Engineeringmentioning
confidence: 99%