2018
DOI: 10.1016/j.engstruct.2018.06.005
|View full text |Cite
|
Sign up to set email alerts
|

Experimental and analytical characterization of steel shear links for seismic energy dissipation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
26
0
3

Year Published

2019
2019
2022
2022

Publication Types

Select...
5
2
1

Relationship

2
6

Authors

Journals

citations
Cited by 55 publications
(29 citation statements)
references
References 16 publications
0
26
0
3
Order By: Relevance
“…For more details about the design and testing of UFP dampers, please refer to Ponzo et al (2019). The proposed procedure is valid also for shear link devices, such as those proposed by Nuzzo et al (2018), as an alternative to UFP dampers if they do not modify the pattern of vertical loads in the beam. The design assumptions have been verified through non-linear time history analyses performed considering the numerical model of Figure 6 and the input motions of Figure 5, as reported in the following paragraph.…”
Section: Are Summarized Inmentioning
confidence: 99%
“…For more details about the design and testing of UFP dampers, please refer to Ponzo et al (2019). The proposed procedure is valid also for shear link devices, such as those proposed by Nuzzo et al (2018), as an alternative to UFP dampers if they do not modify the pattern of vertical loads in the beam. The design assumptions have been verified through non-linear time history analyses performed considering the numerical model of Figure 6 and the input motions of Figure 5, as reported in the following paragraph.…”
Section: Are Summarized Inmentioning
confidence: 99%
“…3. It must be noted that developments on steel profile optimization have been also involved in earthquake engineering [4]. The proposed CFP has been obtained through a multi-criteria process that took into account the objectives described below:…”
Section: System Descriptionmentioning
confidence: 99%
“…1) Flexural capacity: considering a common span of 5m (column-column distance for housing project), the flexural demand of the CFS has been set equal to 30kNm for a 1m-width slab under service loads with the corresponding mid-span deflection not exceeding the Eurocode limit [4], i.e. span length/500.…”
Section: System Descriptionmentioning
confidence: 99%
See 1 more Smart Citation
“…In this work, the fragility curve of the SL damper is constructed. This device, consisting in a steel plate milled in correspondence of its web, where energy dissipation is concentrated, has been recently object of a wide experimental campaign [16]. Gathered data are used in order to get the corresponding fragility curve.…”
Section: Introductionmentioning
confidence: 99%