2013
DOI: 10.1016/j.ijepes.2012.07.027
|View full text |Cite
|
Sign up to set email alerts
|

Experimental analysis of a solar PV/diesel hybrid system without storage: Focus on its dynamic behavior

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
14
0
2

Year Published

2015
2015
2019
2019

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 32 publications
(16 citation statements)
references
References 34 publications
0
14
0
2
Order By: Relevance
“…Additionally on the cloudy day and sunny day under this strategy, the voltage value during the tests ranged from 225.5V to 231V. According to the standard EN 50160, the variation of the voltage should be in the range of ±10% of the nominal value (230V) [8]. On the two days considered the same voltage fluctuation level in the order of 2% has been observed.…”
Section: Voltage and Frequency Fluctuation Frommentioning
confidence: 99%
See 2 more Smart Citations
“…Additionally on the cloudy day and sunny day under this strategy, the voltage value during the tests ranged from 225.5V to 231V. According to the standard EN 50160, the variation of the voltage should be in the range of ±10% of the nominal value (230V) [8]. On the two days considered the same voltage fluctuation level in the order of 2% has been observed.…”
Section: Voltage and Frequency Fluctuation Frommentioning
confidence: 99%
“…Experimental Analysis The integration of a PV system into a microgrid like hybrid PV/Diesel system including a diesel generator can have significant impacts on power quality in general and especially on voltage and frequency as investigated in [8]. In the following sub-section, the energy system's frequency and voltage under the energy management strategies proposed are presented and discussed.…”
Section: Voltage and Frequency Fluctuation Frommentioning
confidence: 99%
See 1 more Smart Citation
“…These studies confirmed that the energy consumption in street lighting system is considerably reduced with PV power source. However, these works focused only on the technical feasibility [4][5][6][7][8][9][10][11], and it's much difficult to find studies on the sustainable and exhaustive feasibility in literature which require an analysis of electrical quality of power supply installation in accordance with EN50160 standard [12,13], and the quality of the electrical network consistent with the standards CE161000-2-2 [14] and CEI61000-3-4 [15].…”
Section: Introductionmentioning
confidence: 99%
“…When several Diesel generators operate in parallel, the whole PV/Diesel hybrid system is subject to two main requirements to ensure its reliability. They are: the frequency and the voltage stabilities at any point of the electrical grid [25,26]. To ensure this, one approach is to use a single Diesel generator (master) to set the frequency.…”
Section: Introductionmentioning
confidence: 99%