2013
DOI: 10.1016/j.jngse.2013.09.003
|View full text |Cite
|
Sign up to set email alerts
|

Experiment research of dynamic stray current interference on buried gas pipeline from urban rail transit

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
30
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 61 publications
(32 citation statements)
references
References 4 publications
0
30
0
Order By: Relevance
“…Although cathodic protection (CP) is widely used in corrosion prevention, conditions that are often encountered in practice such as stray currents 1 or CP currents shielding 2,3 could significantly affect its effectiveness. Unfortunately, methods to evaluate corrosion rates under CP are uncommon and seriously limited.…”
mentioning
confidence: 99%
“…Although cathodic protection (CP) is widely used in corrosion prevention, conditions that are often encountered in practice such as stray currents 1 or CP currents shielding 2,3 could significantly affect its effectiveness. Unfortunately, methods to evaluate corrosion rates under CP are uncommon and seriously limited.…”
mentioning
confidence: 99%
“…ω ih (4,m) ω ih (3,m) ω ih (1,1) ω ih (2,1) ω ih (4,m) ω ih (2,m) ω ih (1,m) ω ih (4,1) ω ih (3,1) ω ho (1,1) ω ho (m,1) ω ho (1,1) ω ho(m,1) ω ih (1,1) Cl% ORP Figure 7: Structure of the ANN and encoding details in QPSO. 8 Complexity function corresponding to the number of hidden nodes.…”
Section: Corrosion Current Density Prediction Andmentioning
confidence: 99%
“…Stray current leakage and its corrosion in the direct current (DC) mass transit system are shown in Figure 1. Stray current will cause electrochemical corrosion in some of the infrastructure, such as the running rails [2], buried pipelines [3], and concrete structures [4,5], which overall reduces the safety performance of the DC mass transit system. In particular, it needs to be explained that most pipelines consist of carbon steel, which makes corrosion one of the most common integrity threats of these systems [6].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…These coatings are also severely affected by various long-term corrosion factors in the soil during the life of the pipe and its service, and these factors often cause coating disbonding. Corrosive media, such as soil solutions, infiltrate into the interface between the pipeline and the damaged coating, forming a favorable corrosion microenvironment and corroding the pipeline [1,2]. Stray currents refer to the currents that occur outside of a specific loop.…”
Section: Introductionmentioning
confidence: 99%