2024
DOI: 10.1016/j.enbenv.2023.01.002
|View full text |Cite
|
Sign up to set email alerts
|

Experiment and simulation to determine the optimum orientation of building-integrated photovoltaic on tropical building façades considering annual daylight performance and energy yield

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
2
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 14 publications
(7 citation statements)
references
References 62 publications
0
2
0
Order By: Relevance
“…The validation results also suggest, in line with [89], that the difference between the data obtained on site and the simulation results for different orientations is relatively small, allowing the behavior model obtained to be extrapolated beyond the simulation phase. However, it is important to note that the results are not entirely free from occasional uncertainty, as they have to account for climatic variability, which, in the case of Granada, tends to lead to rising temperatures in both studied periods.…”
Section: Room Performance In Extreme Temperaturessupporting
confidence: 78%
See 1 more Smart Citation
“…The validation results also suggest, in line with [89], that the difference between the data obtained on site and the simulation results for different orientations is relatively small, allowing the behavior model obtained to be extrapolated beyond the simulation phase. However, it is important to note that the results are not entirely free from occasional uncertainty, as they have to account for climatic variability, which, in the case of Granada, tends to lead to rising temperatures in both studied periods.…”
Section: Room Performance In Extreme Temperaturessupporting
confidence: 78%
“…The results of this study align with previous research [87,88], confirming that a north orientation offers good thermal performance when combined with low WWR. Additionally, the best results are obtained with a northwest orientation, in contrast to [89,90], which reported more favorable results for south and east orientations based on their geographical context. This emphasizes the impact of orientation in such studies.…”
Section: Influence Of Thermal Transmittance and Orientation In The Roomsmentioning
confidence: 93%
“…The performance of BIPV systems is affected by several parameters, such as building orientation, panel slope, solar cell type, ambient temperature, geographical location, and shading [30]. In fact, in terms of geographical location, due to a higher amount of solar radiation near to zenith, in tropical regions BIPV were mostly installed on roofs [31]. In contrast, in non-tropical regions, the amount of solar radiation near to zenith decreases with latitude, which reduces the electricity production in roof solar PV panels, while favouring the electricity production in panels placed on vertical walls.…”
Section: Building Energy Modelling and Pv Systems In The Urban Enviro...mentioning
confidence: 99%
“…Recent years have seen tremendous advances in this technology, which has established itself as a well-known renewable energy source with noteworthy advantages such as reduced carbon dioxide emissions, a quick payback period, adaptability to a variety of situations, and durability in adverse environments. Unfortunately, a number of variables that affect it-such as dust accumulation, reflection, angle of inclination variation, orientation, shading effects, radiation exposure, and temperature-cause this technology to display a comparatively lower degree of conversion efficiency [19][20][21][22][23][24][25]. [18].…”
Section: Pv Technologymentioning
confidence: 99%