2015
DOI: 10.1016/j.injury.2015.06.024
|View full text |Cite
|
Sign up to set email alerts
|

Expanding indications of the horizontal belt plate: A technical note

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 7 publications
0
5
0
Order By: Relevance
“…17 A smallfragment nonlocked or locked plate is precontoured and inserted from lateral to medial, so it sits exactly on the PL proximal aspect of the tibial plateau, parallel and closer to the articular joint line, wrapping the avulsed fracture fragments. 1,33 The plate should be completely adjusted to the bone anatomy of the PL corner of the knee. There is no room to place screws from the posterior to the anterior lateral tibial plateau, so the screws should be inserted from the lateral to the medial tibial plateau (►Fig.…”
Section: Surgical Techniques For Reconstruction Based On the Type Of mentioning
confidence: 99%
See 1 more Smart Citation
“…17 A smallfragment nonlocked or locked plate is precontoured and inserted from lateral to medial, so it sits exactly on the PL proximal aspect of the tibial plateau, parallel and closer to the articular joint line, wrapping the avulsed fracture fragments. 1,33 The plate should be completely adjusted to the bone anatomy of the PL corner of the knee. There is no room to place screws from the posterior to the anterior lateral tibial plateau, so the screws should be inserted from the lateral to the medial tibial plateau (►Fig.…”
Section: Surgical Techniques For Reconstruction Based On the Type Of mentioning
confidence: 99%
“…An alternative to this, mainly when there is a poor bone stock, is to use a horizontal nonlocked or locked plate as a big washer. 1, 17,27,32,33 Additional two to three anterolateral-to-PL 2.7-mm or 3.5-mm cortical screws with washers are introduced in a "jail technique" to prevent screw cut-out. 41 Careful measurement of the screws is important, as long screws posteriorly can damage overlying soft tissues.…”
Section: Surgical Techniques For Reconstruction Based On the Type Of mentioning
confidence: 99%
“…11 ). This technique expands the applications of the horizontal plating concept [ 18 , 19 , 23 , 24 , 49 , 50 ], offering a novel alternative that allows direct control and proximal screw fixation of the PL column through the MOL approach.…”
Section: Discussionmentioning
confidence: 99%
“…At the distal end of the plate, a regular anatomical locking plate was also used for fixing the proximal tibia. In 2017, Pires et al 10 reported using a horizontal rafting plate for treating a tibial plateau fracture, with the posterolateral side involved. The surgeries were conducted via the fibular neck osteotomy approach to expose the posterolateral plateau.…”
Section: Fixation Of the Fracture Of The Posterolateral Tibial Plateaumentioning
confidence: 99%
“…In their study, the conventional reconstruction plate was shaped along the shape of the tibial plateau at the level of the articular rim of the tibial plateau, which was fixed using several screws at different levels. At present, this method is used for the accessory treatment of periarticular fractures, such as fractures of the distal femur, ankle, and proximal humerus 10 . However, for the fracture of the posterolateral tibial plateau, fixation is influenced by the fibula, making fixation very difficult.…”
Section: Introductionmentioning
confidence: 99%