2012
DOI: 10.1111/j.1442-200x.2011.03515.x
|View full text |Cite
|
Sign up to set email alerts
|

Exhaled carbon monoxide levels in preschool‐age children with episodic asthma

Abstract: The measurement of eCO using a novel collecting system is useful in the recognition of asthma in preschool children.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(11 citation statements)
references
References 25 publications
(42 reference statements)
0
11
0
Order By: Relevance
“…In most studies, eCO values have been measured with electrochemical devices, which are cheaper and more easily transportable than laser spectrophotometers, near-infrared analysers [ 25 , 26 ] or photo acoustic spectrometers [ 22 ]. Among electrochemical devices, PiCO+ has been utilized both for monitoring smoking habits (which is its primary target) [ 27 29 ] and for assessing eCO levels in several diseases [ 8 , 9 , 11 17 ]. Normal eCO values were not exactly comparable even across studies that utilized this device, since mean values in non-smoker subjects varied from less than 1.5 [ 15 ] to 3 ppm [ 17 ].…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…In most studies, eCO values have been measured with electrochemical devices, which are cheaper and more easily transportable than laser spectrophotometers, near-infrared analysers [ 25 , 26 ] or photo acoustic spectrometers [ 22 ]. Among electrochemical devices, PiCO+ has been utilized both for monitoring smoking habits (which is its primary target) [ 27 29 ] and for assessing eCO levels in several diseases [ 8 , 9 , 11 17 ]. Normal eCO values were not exactly comparable even across studies that utilized this device, since mean values in non-smoker subjects varied from less than 1.5 [ 15 ] to 3 ppm [ 17 ].…”
Section: Discussionmentioning
confidence: 99%
“…V tube = volume of the sampling tube = 3.14 × 0.15 2 × 100 = 7.07 mL Bedfont EC50 PiCO + Smokerlyzer (PiCO+) (Bedfont Scientific, Kent, UK) is a small, portable device primarily aimed to distinguish smokers from non-smokers and to classify smokers on the basis of their smoking habits. It has been also utilized in many studies that investigated eCO levels in respiratory diseases [ 8 , 9 , 11 18 ]. This instrument utilizes an electrochemical sensor to analyse exhaled air for eCO concentration and has a detection limit of 1 ppm.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…In childhood asthma patients, eCO values were found to be independent of expiratory flow rate [123]. Recent studies in preschool children report that eCO values were higher during asthma attacks relative to levels recorded in asymptomatic asthma subjects or healthy controls, and these values were normalized during combination inhalation therapy with salbutamol and sodium cromoglycate [124]. eCO levels were also found to correlate with allergic seasonal rhinitis, which returned to control values at the end of the allergen season [125-126].…”
Section: Carbon Monoxide In Exhaled Breathmentioning
confidence: 99%
“…Recently, it has been reported in preschool-aged children, that eCO levels in those with asthma attacks were significantly higher as these in healthy children. eCO levels during asthma attacks significantly decreased after inhalation therapy with a combination of a 2-agonist and sodium cromoglycate (Ohara, et al, 2012). Apart from asthma, other diseases such as allergic rhinitis, bronchiectasis, lower and upper respiratory tract infections, interstitial lung disease and cystic fibrosis have also shown an increased production of eCO.…”
Section: Production Of Co and "Gas-sensors"mentioning
confidence: 99%