2016
DOI: 10.1016/j.apenergy.2015.10.122
|View full text |Cite
|
Sign up to set email alerts
|

Exergoeconomic and environmental analyses of an air conditioning system using thermal energy storage

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
20
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 94 publications
(20 citation statements)
references
References 28 publications
0
20
0
Order By: Relevance
“…Mosaffa and Farshi combined an LHTS with a refrigeration system (Figure ) and then analyzed its exergoeconomic and environmental performance. Three cases with different PCM slab sizes and PCMs (RT27, S27, and SP25) were then analyzed.…”
Section: Review Of Studies On Improving the Performance Of Air Conditmentioning
confidence: 99%
See 1 more Smart Citation
“…Mosaffa and Farshi combined an LHTS with a refrigeration system (Figure ) and then analyzed its exergoeconomic and environmental performance. Three cases with different PCM slab sizes and PCMs (RT27, S27, and SP25) were then analyzed.…”
Section: Review Of Studies On Improving the Performance Of Air Conditmentioning
confidence: 99%
“…Schematic representation of the air cooling system incorporating a LHTS unit [Colour figure can be viewed at wileyonlinelibrary.com]…”
Section: Review Of Studies On Improving the Performance Of Air Conditmentioning
confidence: 99%
“…The main methods have been reviewed for modeling and assessing performance of stratified thermal storage (Njoku et al 2014). Further, techno-economic assessments of heat and cold thermal storage systems have been applied, often using advanced methods like exergoeconomics (economics based on exergy) (Rosen 2011;Mosaffa and Garousi Farshi 2016). The economics of thermal storage systems in conjunction with cogeneration, trigeneration and DE have also been the subject of numerous investigations (Rentizelas et al 2009;Lozano et al 2009aLozano et al , 2010Balli et al 2010;Dominković et al 2015), including thermoeconomic analyses (Balli et al 2010) and economic optimization of designs (Lozano et al 2010).…”
Section: Modeling Analysis and Optimizationmentioning
confidence: 99%
“…Mostaffa et al [13] present air conditioning system in the form of combination of a latent heat thermal storage unit and a refrigeration system. Figure 4 shows the schematic of the system.…”
mentioning
confidence: 99%
“…4. Schematic of the air cooling system incorporating a latent heat thermal storage unit [13] Zhao and Tank [14] present in their work possibility of integration of shell-and-tube based phase change material (PCM) thermal storage system with conventional air-conditioner. The proposed system use water (for charging loop) and air (for discharging loop) as a media for the heat transfer fluid.…”
mentioning
confidence: 99%