2012
DOI: 10.1021/ac300127s
|View full text |Cite
|
Sign up to set email alerts
|

Exciton-Plasmon Interactions between CdS Quantum Dots and Ag Nanoparticles in Photoelectrochemical System and Its Biosensing Application

Abstract: With DNA as a rigid spacer, Ag nanoparticles (NPs) were bridged to CdS quantum dots (QDs) for the stimulation of exciton-plasmon interactions (EPI) in a photoelectrochemical (PEC) system. Due to their natural absorption overlap, the exciton of the QDs and the plasmon of Ag NPs could be induced simultaneously. The EPI resonant nature enabled manipulating photoresponse of the QDs via tuning interparticle distances. Specifically, the photocurrent of the QDs could be greatly attenuated and even be completely dampe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
131
0
1

Year Published

2014
2014
2022
2022

Publication Types

Select...
9
1

Relationship

2
8

Authors

Journals

citations
Cited by 175 publications
(132 citation statements)
references
References 52 publications
0
131
0
1
Order By: Relevance
“…1D) has a large spectral overlap with the fluorescence emission of CdTe-MWCNTs/rGONRs (Fig. 1B), which provided the possibility for the RET [13,28].…”
Section: Characterization Of Au Nrs and Au Nrs-dna2mentioning
confidence: 99%
“…1D) has a large spectral overlap with the fluorescence emission of CdTe-MWCNTs/rGONRs (Fig. 1B), which provided the possibility for the RET [13,28].…”
Section: Characterization Of Au Nrs and Au Nrs-dna2mentioning
confidence: 99%
“…3B showed a good linear correlation of the current response difference (ΔI¼I miR-21 -I blank ) to the logarithm of the miR-21concentrations (logC miR-21 ) ranged from 1 aM to 100 pM, with a regression equation of ΔI/μA¼0.6904þ0.0234 logC miR-21 /M (R 2 ¼0.997). This kind of logarithmic relationship between the response signals with the concentration of target biomolecules is widely used for various DNA/miR biosensors Liu et al, 2008;Zhao et al, 2012a;Fan et al, 2014;Shi et al, 2016;Li et al, 2016), immunosensors (Kang et al, 2010) and cytosensors (Zhao et al, 2012b). The main reason for this phenomenon might be due to the intrinsic property of ligandreceptor bio-recognition.…”
Section: Sensitivity Of Mir-21 Assaymentioning
confidence: 99%
“…Analysts in this field are now infatuated with exploiting exquisite signaling mechanisms for innovative applications (Zhang et al, 2012b;Zhuang et al, 2015;Wang et al, 2015;Long et al, 2011;Wang et al, 2014a, Sun et al, 2015. Among various efforts, exciton-plasmon interactions (EPI) between the noble metal nanoparticles (NPs) and quantum dots (QDs) have been demonstrated as a unique route for ingenious PEC biosensing purposes , Zhao et al, 2012. Such interesting mechanism was then used for tentative bioanalysis with a simple DNA hybridization model, which provided a feasible basis for elegant PEC bioassays and many recent protocols were proposed for addressing different targets (Zeng et al, 2013;Ma et al, 2016).…”
Section: Introductionmentioning
confidence: 99%