1997
DOI: 10.1524/ract.1997.76.12.3
|View full text |Cite
|
Sign up to set email alerts
|

Excitation Functions of some Neutron Threshold Reactions on 89Y in the Energy Range of 7.8 to 14.7 MeV

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
15
0

Year Published

1999
1999
2019
2019

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 28 publications
(18 citation statements)
references
References 16 publications
(20 reference statements)
3
15
0
Order By: Relevance
“…For ascertaining the constancy of the neutron flux, a constant check of the D 2 gas pressure in the cell and of the deuteron beam current on the target was performed. The neutron flux density effective during each irradiation was determined via two monitor reactions, namely, 56 Fe(n, p) 56 Mn (T 1/2 = 2.58 h, E γ = 847 keV, I γ = 98.9%), and 27 Al(n, α) 24 Na (T 1/2 = 14.97 h, E γ = 1369 keV, I γ = 100%). The cross sections of the monitor reactions were taken from the International Reactor Dosimetry File [24].…”
Section: B Neutron Energies and Flux Densitiesmentioning
confidence: 99%
See 1 more Smart Citation
“…For ascertaining the constancy of the neutron flux, a constant check of the D 2 gas pressure in the cell and of the deuteron beam current on the target was performed. The neutron flux density effective during each irradiation was determined via two monitor reactions, namely, 56 Fe(n, p) 56 Mn (T 1/2 = 2.58 h, E γ = 847 keV, I γ = 98.9%), and 27 Al(n, α) 24 Na (T 1/2 = 14.97 h, E γ = 1369 keV, I γ = 100%). The cross sections of the monitor reactions were taken from the International Reactor Dosimetry File [24].…”
Section: B Neutron Energies and Flux Densitiesmentioning
confidence: 99%
“…The count rate of each γ ray was corrected for coincidence summing effect, geometric effect of the HgCl 2 sample, and γ -ray selfattenuation in the sample. Furthermore, in order to determine the counting efficiency for the extended source placed directly on the end cap of the detector, a radioactive source especially prepared was used as in two earlier cases [27,28]. For this purpose, 10 mg samples of HgCl 2 and Eu 2 O 3 were irradiated using a 14 MeV d(Be) neutron source, and the induced activity in each sample was assayed via γ -ray spectrometry.…”
Section: Measurement Of Radioactivitymentioning
confidence: 99%
“…Typical individual uncertainties were estimated as described in the literature [cf. 42,43]; they are given in Table 1. The overall error for each reaction cross section was obtained by summing the individual errors in quadrature.…”
Section: Calculation Of Cross Sections and Their Uncertaintiesmentioning
confidence: 99%
“…between 2 and 6 MeV. The excitation functions of the 67 Zn(n, p) 67 Cu and 89 Y(n, p) 89 Sr reactions, measured radiochemically [15,16], are shown in Fig. 3.…”
Section: β − -Emittersmentioning
confidence: 99%