2005
DOI: 10.1002/chem.200500069
|View full text |Cite
|
Sign up to set email alerts
|

Excitation‐Energy Migration in Self‐Assembled Cyclic Zinc(II)–Porphyrin Arrays: A Close Mimicry of a Natural Light‐Harvesting System

Abstract: The excitation-energy-hopping (EEH) times within two-dimensional cyclic zinc(II)-porphyrin arrays 5 and 6, which were prepared by intermolecular coordination and ring-closing metathesis reaction of olefins, were deduced by modeling the EEH process based on the anisotropy depolarization as well as the exciton-exciton annihilation dynamics. Assuming the number of energy-hopping sites N = 5 and 6, the two different experimental observables, that is, anisotropy depolarization and exciton-excition annihilation time… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
46
0
1

Year Published

2008
2008
2023
2023

Publication Types

Select...
3
3

Relationship

1
5

Authors

Journals

citations
Cited by 85 publications
(49 citation statements)
references
References 71 publications
(18 reference statements)
2
46
0
1
Order By: Relevance
“…already been observed [47,51,60] and measurements of the EEH rates for a series of systematic ring variations of this study may extend this tendency. Further studies are ongoing.…”
Section: -Mer ð 11-mer ðCþmentioning
confidence: 51%
See 4 more Smart Citations
“…already been observed [47,51,60] and measurements of the EEH rates for a series of systematic ring variations of this study may extend this tendency. Further studies are ongoing.…”
Section: -Mer ð 11-mer ðCþmentioning
confidence: 51%
“…This observation was supported by a gradual increase of the coupling interactions of porphyrin transition dipoles. [47,51] Experimental Section General: Analytical GPC was performed on a Hewlett-Packard HP1100 series instrument using a JAIGEL 3H-A column (Japan Analytical Industry, polystyrene gel, diameter = 8 mm, length = 50 cm, exclusion limit = 70 000 Da, eluent: CHCl 3 /0.05 % Et 3 N) or a Shimadzu LC workstation M10 equipped with an SPD-M10 AVP photodiode array detector using a Tosoh TSK-GEL G3000H HR column (polystyrene gel, exclusion limit = 60 000 Da). Recycling GPC was carried out on a recycling GPC-HPLC system (Japan Analytical Industry, LC-908) connected with two series columns (JAIGEL 3HA, diameter = 20 mm, length = 60 cm 2, polystyrene, exclusion limit = 70 000 Da, eluent: CHCl 3 /0.05 % Et 3 N), or two series columns of Tosoh TSK-GEL G3000H HR (polystyrene gel, exclusion limit = 60 000 Da, eluent: pyridine).…”
Section: Resultsmentioning
confidence: 97%
See 3 more Smart Citations