The platform will undergo maintenance on Sep 14 at about 9:30 AM EST and will be unavailable for approximately 1 hour.
2018
DOI: 10.4103/0366-6999.237395
|View full text |Cite
|
Sign up to set email alerts
|

Excitation-Contraction Coupling Time is More Sensitive in Evaluating Cardiac Systolic Function

Abstract: Background:Pressure overload-induced myocardial hypertrophy is a key step leading to heart failure. Previous cellular and animal studies demonstrated that deteriorated excitation–contraction coupling occurs as early as the compensated stage of hypertrophy before the global decrease in left ventricular ejection fraction (LVEF). This study was to evaluate the cardiac electromechanical coupling time in evaluating cardiac systolic function in the early stage of heart failure.Methods:Twenty-six patients with Stage … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
2
1

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 23 publications
0
4
0
Order By: Relevance
“…HR is related to the electrical and mechanical activities of the heart ( 18 ). We determined all the data of electromechanical coupling time courses with HR correction, referenced as the formula in a previous study: electromechanical coupling time courses with HR correction = electromechanical coupling time courses without HR correction/HR × 60 ( 12 , 18 ).…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…HR is related to the electrical and mechanical activities of the heart ( 18 ). We determined all the data of electromechanical coupling time courses with HR correction, referenced as the formula in a previous study: electromechanical coupling time courses with HR correction = electromechanical coupling time courses without HR correction/HR × 60 ( 12 , 18 ).…”
Section: Methodsmentioning
confidence: 99%
“…Cardiac excitation-contraction coupling is a process that links cardiomyocyte action potential to cardiomyocyte contractile ( 11 ). The process is difficult to test experimentally; nevertheless, cardiac electromechanical coupling efficiency, presented as electromechanical coupling time, previously evaluated by combining tissue Doppler imaging (TDI) echo and electrocardiogram (ECG) measurement has been proven ( 12 ). In a preliminary study, electromechanical coupling time was proposed as a potential index for evaluating cardiac systolic function in patients with stage B HF, which is a precursor of HF ( 12 , 13 ).…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…ECG was performed using a Vevo 2,100 system (FUJIFILM VisualSonics, Canada), and the cardiac dimensions and functional parameters were measured. The tissue Doppler imaging (TDI) echo combined with ECG was used to measure the electromechanical coupling time at the lateral wall of the left ventricle as described previously (19).…”
Section: Ecg and Electromechanical Coupling Time Measurementmentioning
confidence: 99%