2010
DOI: 10.1134/s1023193510020126
|View full text |Cite
|
Sign up to set email alerts
|

Exchange kinetics and diffusion of oxygen in systems based on lanthanum gallate

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 22 publications
(3 citation statements)
references
References 12 publications
0
3
0
Order By: Relevance
“…The scheme of the experimental rig is reported elsewhere. 13 Preliminary to the isotope exchange the sample underwent pre-treatment at 800 1C in oxygen. To prevent the obstacle of oxygen gas diffusion a circulation pump was applied.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The scheme of the experimental rig is reported elsewhere. 13 Preliminary to the isotope exchange the sample underwent pre-treatment at 800 1C in oxygen. To prevent the obstacle of oxygen gas diffusion a circulation pump was applied.…”
Section: Methodsmentioning
confidence: 99%
“…The power index of r H is governed by the power index of adsorption rate and is close to 0.5 which is in accordance with Langmuir's model of the dissociative adsorption. The abovementioned considerations are based on the comparison of the mean values of r a and r i , however, the fact that ratio (13) is not equal to unity allows us to conclude that the oxygen incorporation rate has a relatively broad distribution. The oxygen incorporation rate value can be 1-2 orders of magnitude higher compared to the adsorption rate for the grains with the (ab)-crystallographic orientation (that corresponds to the dissociative adsorption being the rate-determining stage).…”
Section: Oxygen Surface Exchange Kineticsmentioning
confidence: 99%
“…Enriched 18 O oxygen was used as a label, the proportion of which in the mixture was 83.6%. A detailed description of the experimental procedure, the assessment of the accuracy of the determination of the heterogeneous exchange rate (r H , atom cm −2 s −1 ) and the oxygen diffusion coefficient (D, cm 2 s −1 ), and the calculation of the dissociative adsorption rate (r a , atom cm −2 s −1 ) and the oxygen incorporation rate (r i , atom cm −2 s −1 ) are described in [35][36][37]. During the experiment, periodical changes in the ion current corresponding to the masses 32, 34, and 36 ( 16 O 2 , 16 O 18 O, 18 O 2 ) were recorded using a quadrupole mass spectrometer Agilent 5973N.…”
Section: Methodsmentioning
confidence: 99%