Examination of Inertial Sensor-Based Estimation Methods of Lower Limb Joint Moments and Ground Reaction Force: Results for Squat and Sit-to-Stand Movements in the Sagittal Plane

Abstract: Joint moment estimation by a camera-based motion measurement system and a force plate has a limitation of measurement environment and is costly. The purpose of this paper is to evaluate quantitatively inertial sensor-based joint moment estimation methods with five-link, four-link and three-link rigid body models using different trunk segmented models. Joint moments, ground reaction forces (GRF) and center of pressure (CoP) were estimated for squat and sit-to-stand movements in the sagittal plane measured with … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
44
1

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 19 publications
(46 citation statements)
references
References 38 publications
(51 reference statements)
1
44
1
Order By: Relevance
“…However, pursuing the accuracy makes it difficult to use in the clinics as more factors should be considered or more sensors are required 23,24) . Kodama et al 10) required at least total 32 parameters in both horizontal and vertical for estimation of joint moments. However, the prediction formulas in this study created from maximum 9 parameters using only three sensors and can obtain good to excellent correlations between actual joint moments for most of the motions.…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…However, pursuing the accuracy makes it difficult to use in the clinics as more factors should be considered or more sensors are required 23,24) . Kodama et al 10) required at least total 32 parameters in both horizontal and vertical for estimation of joint moments. However, the prediction formulas in this study created from maximum 9 parameters using only three sensors and can obtain good to excellent correlations between actual joint moments for most of the motions.…”
Section: Discussionmentioning
confidence: 99%
“…Three Wearable inertial motion sensors (LP-WSD1101-OA Ver.1.0.0, 1,000 Hz, LOGICAL PRODUCT, Fukuoka, Japan) were attached to the outside of right limbs by using double-sided adhesive tape 10) (Fig. 1).…”
Section: Participants and Methodsmentioning
confidence: 99%
See 3 more Smart Citations