2010
DOI: 10.1088/0031-9155/55/4/007
|View full text |Cite
|
Sign up to set email alerts
|

Exact analytic reconstruction in x-ray fluorescence CT and approximated versions

Abstract: X-ray fluorescence computed tomography (XFCT) is a relatively new synchrotron-based imaging modality aiming at reconstructing the distribution of nonradiative elements within a sample irradiated with high-intensity monochromatic x-rays. In a recent paper La Rivière (2004 Phys. Med. Biol. 49 2391-405) presented an approximated inversion method based on reducing the problem to the inversion of the exponential radon transform. In this paper we compare La Rivière's results with recently derived 'exact' analytic fo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
14
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
4
4
1

Relationship

0
9

Authors

Journals

citations
Cited by 42 publications
(14 citation statements)
references
References 25 publications
0
14
0
Order By: Relevance
“…In order to minimze the detection of elastic and Compton scattered photons and improve the signal-to-background ratio, the fluorescence detector is positioned 90° from the incident beam. 102, 107108 X-ray transmittance is simultaenously acquired using a conventional CT detector in order to provide co-registered XRF and CT images. Samples are scanned and rotated through a series of angles and the emitted fluorescence intensity is collected at each orientation.…”
Section: X-ray Fluorescence (Xrf)mentioning
confidence: 99%
“…In order to minimze the detection of elastic and Compton scattered photons and improve the signal-to-background ratio, the fluorescence detector is positioned 90° from the incident beam. 102, 107108 X-ray transmittance is simultaenously acquired using a conventional CT detector in order to provide co-registered XRF and CT images. Samples are scanned and rotated through a series of angles and the emitted fluorescence intensity is collected at each orientation.…”
Section: X-ray Fluorescence (Xrf)mentioning
confidence: 99%
“…In the XFCT literature, the scattering effect is treated as noise. 25 In the XLCT work, the Stanford group that developed XLCT has implicitly assumed that the stimulating x-rays traveled strictly in straight lines. 6 To address this source of inaccuracy, the x-ray scattering compensation as we have showcased in this paper must be a key step for either XLCT or XFCT, and especially for the former.…”
Section: Discussionmentioning
confidence: 99%
“…In addition to the construction of the Inverse attenuated Radon transform, the approach reviewed here has led to the construction of the X-ray fluorescence computed tomography [20].…”
Section: The Inverse Radon Transform and The Inverse Attenuated Radonmentioning
confidence: 99%