2015
DOI: 10.2147/mder.s63350
|View full text |Cite
|
Sign up to set email alerts
|

EX-PRESS Glaucoma Filtration Device: efficacy, safety, and predictability

Abstract: Trabeculectomy has been the traditional primary surgical therapy for open-angle glaucoma. While trabeculectomy is effective in lowering intraocular pressure, complications associated with the procedure have motivated the development of alternative techniques and devices, including the EX-PRESS Glaucoma Filtration Device. This review describes the efficacy, safety, complication rates, and potential advantages and disadvantages of the EX-PRESS Glaucoma Filtration Device. EX-PRESS implantation is technically simp… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(12 citation statements)
references
References 28 publications
(62 reference statements)
0
8
0
Order By: Relevance
“…A 25-G needle was then passed into the AC from under the flap and the EX-PRESS (P-50 model) was placed into the sclerostomy as described previously. 16 After reapproximation of the scleral flap with 10-0 nylon sutures, the conjunctiva was closed in a water tight fashion using 8-0 vicryl suture. Two wing sutures were used for all closures.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…A 25-G needle was then passed into the AC from under the flap and the EX-PRESS (P-50 model) was placed into the sclerostomy as described previously. 16 After reapproximation of the scleral flap with 10-0 nylon sutures, the conjunctiva was closed in a water tight fashion using 8-0 vicryl suture. Two wing sutures were used for all closures.…”
Section: Methodsmentioning
confidence: 99%
“…A fornix-based conjunctival flap was created superiorly, and a partial-thickness scleral flap was constructed at the limbus. A 25-G needle was then passed into the AC from under the flap and the EX-PRESS (P-50 model) was placed into the sclerostomy as described previously 16. After reapproximation of the scleral flap with 10-0 nylon sutures, the conjunctiva was closed in a water tight fashion using 8-0 vicryl suture.…”
Section: Methodsmentioning
confidence: 99%
“…Trabeculectomy (TBC) was introduced by Cairns in 1968 as a surgical procedure for glaucoma, and it is the procedure of choice for surgical open-angle glaucoma treatment. 3 …”
Section: Introductionmentioning
confidence: 99%
“… 4 , 5 These complications have motivated the development of alternative techniques and devices, including the EX-PRESS ® glaucoma filtration device. 3 , 6 …”
Section: Introductionmentioning
confidence: 99%
“…However, complications such as erosion, displacement, and blockage of the implant, as well as hypotony are commonly reported. 231…”
Section: Microfluidics Of Minimally Invasive Glaucoma Surgery (Migs) ...mentioning
confidence: 99%