2015
DOI: 10.1016/j.foodchem.2015.01.090
|View full text |Cite
|
Sign up to set email alerts
|

Evolution of phenolic compounds and metal content of wine during alcoholic fermentation and storage

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

6
49
1
2

Year Published

2016
2016
2024
2024

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 71 publications
(64 citation statements)
references
References 35 publications
(51 reference statements)
6
49
1
2
Order By: Relevance
“…From the literature it is well known that anthocyanintype pigments can cause great interference in the chromatographic separation and identification of non-anthocyanin phenolic compounds. 36 In our study, anthocyanins were successfully removed using HLB cartridges. Another advantage of HLB cartridges over conventional C18 columns in the separation of phenolic compounds are that more polar interferences (e.g.…”
Section: Resultsmentioning
confidence: 90%
“…From the literature it is well known that anthocyanintype pigments can cause great interference in the chromatographic separation and identification of non-anthocyanin phenolic compounds. 36 In our study, anthocyanins were successfully removed using HLB cartridges. Another advantage of HLB cartridges over conventional C18 columns in the separation of phenolic compounds are that more polar interferences (e.g.…”
Section: Resultsmentioning
confidence: 90%
“…The chromatographic separation of compounds was based on the method proposed by Bimpilas et al . () for wine samples. For the identification of anthocyanins ElectroSpray Ionization/Mass Spectrometry (ESI/MS) and ESI‐MS/MS was used, employing the following parameters: positive ionization mode, drying gas, N 2 ; drying temperature, 350C; nebulizer, 65 psi; capillary, 2.5 kV; compound stability, 100%; scan range, 100–1,200 m/z .…”
Section: Methodsmentioning
confidence: 99%
“…Samples were injected after filtration (0.2 lm, polyvinylidene fluoride (PVDF) syringe filters, Teknokroma, Barcelona, Spain) on a reversed phase Hypersil C18 column (octadecyl silica (ODS) 5 lm, 250 3 4.6 mm, MZ Analysentechnik, Mainz, Germany). The chromatographic separation of compounds was based on the method proposed by Bimpilas et al (2015) for wine samples. For the identification of anthocyanins ElectroSpray Ionization/Mass Spectrometry (ESI/MS) and ESI-MS/MS was used, employing the following parameters: positive ionization mode, drying gas, N 2 ; drying temperature, 350C; nebulizer, 65 psi; capillary, 2.5 kV; compound stability, 100%; scan range, 100-1,200 m/z.…”
Section: Storage and Shelf Life Studymentioning
confidence: 99%
“…Phenolics are a chemical class including a hydroxyl group (−OH) directly bounded to aromatic ring. They are present as a constitutive agent in plants, which response to microbial attack (Bimpilas, Tsimogiannis, Balta-Brouma, Lymperopoulou, & Oreopoulou, 2015;. Flavonoids are the main class of phenolics and widely dispersed in plants.…”
Section: Introductionmentioning
confidence: 99%