2019
DOI: 10.1111/coa.13327
|View full text |Cite
|
Sign up to set email alerts
|

Evolution of impedance values in two different electrode array designs following activation of cochlear implants 1 day after surgery: A study of 58 patients

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
8
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(9 citation statements)
references
References 10 publications
1
8
0
Order By: Relevance
“…As reported in a previous study using the Nucleus implant system, a signi cant reduction in impedance for all electrode contacts from slim modiolar electrodes was also observed from the early switch-on group in the present study 18,24 . In contrast, other studies using the MED-EL or the Advanced Bionics implant system showed no signi cant decrease in impedance at early switch-on 19,20,25 20,22 . To the best of our knowledge, this is the rst study to report the time course of the postoperative impedance levels for a slim modiolar electrode array.…”
Section: Discussionmentioning
confidence: 67%
See 2 more Smart Citations
“…As reported in a previous study using the Nucleus implant system, a signi cant reduction in impedance for all electrode contacts from slim modiolar electrodes was also observed from the early switch-on group in the present study 18,24 . In contrast, other studies using the MED-EL or the Advanced Bionics implant system showed no signi cant decrease in impedance at early switch-on 19,20,25 20,22 . To the best of our knowledge, this is the rst study to report the time course of the postoperative impedance levels for a slim modiolar electrode array.…”
Section: Discussionmentioning
confidence: 67%
“…Previous studies have identi ed that the time course of impedance values differ according to the type of electrode array, and even within the electrode array the trend of impedance changes varies across the electrode array 18,[20][21][22] . However, longitudinal changes in impedance over the long-term for slim modiolar electrode arrays have not been previously investigated.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The higher EI values in the apical segment may be attributed to the physical characteristics of the Med-El electrode [12]. Furthermore, higher impedance values in the apical segment could be induced by trauma during electrode insertion [13,14].…”
Section: Discussionmentioning
confidence: 99%
“…5 Over the years, several other groups have published their experiences with early activation, ranging from 13 days to the day of surgery in the recovery room. [6][7][8][9][10][11][12][13][14][15][16][17][18][19][20][21] An increasing number of publications from a select group of CI centers suggest increased acceptance of these protocols, although no data exist as to how common this practice is in reality.…”
Section: Historymentioning
confidence: 99%