2023
DOI: 10.2147/opth.s389198
|View full text |Cite
|
Sign up to set email alerts
|

Evidence-Based Consensus Guidelines Series for MicroPulse Transscleral Laser Therapy - Surgical Technique, Post-Operative Care, Expected Outcomes and Retreatment/Enhancements

Abstract: Purpose To provide expert consensus and evidence-based current guidelines on treatment technique, postoperative care, expected outcomes and retreatment for MicroPulse Transscleral Laser Treatment (TLT). Methods A comprehensive search of PubMed led to the identification and analysis of 61 studies on MicroPulse TLT. To provide guidance in areas where there was not enough available literature, a three-round Delphi method was conducted involving 10 international experts in … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 45 publications
0
4
0
Order By: Relevance
“…Repeated procedure was warranted if a minimum of 20% decrease was not seen or target IOP was not reached. Expert consensus guidelines published during the data acquisition and processing of this study recommended power of 2.5 Watts, duty cycle of 31.3% and treatment time of 80 s per hemisphere with a sweep velocity/hemisphere of 20 s/sweep [ 24 , 27 ]. The calculated total energy, dwell times, and fluence of this study are 150 J, 0.63 s, and 51.89 J/cm 2 .…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Repeated procedure was warranted if a minimum of 20% decrease was not seen or target IOP was not reached. Expert consensus guidelines published during the data acquisition and processing of this study recommended power of 2.5 Watts, duty cycle of 31.3% and treatment time of 80 s per hemisphere with a sweep velocity/hemisphere of 20 s/sweep [ 24 , 27 ]. The calculated total energy, dwell times, and fluence of this study are 150 J, 0.63 s, and 51.89 J/cm 2 .…”
Section: Discussionmentioning
confidence: 99%
“…The guidelines [ 24 , 27 ] provide a useful collection of evidence-based consensus mainly on the MicroPulse (IRIDEX) machine. On the other hand, data regarding the safety and the efficacy of the Supra 810 and Vitra 810 (Quantel Medical) machines are scarce [ 37 , 39 , 50 , 51 ].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Diode micropulse has been shown to be effective at least in the intermediate term in refractory glaucoma and is repeatable with similar efficacy across additional treatments. 1,2 In addition, this nonincisional approach preserves the conjunctiva and conventional outflow system should an additional procedure for IOP reduction be required.…”
Section: Mark Gallardo MDmentioning
confidence: 99%