2006
DOI: 10.1007/s10006-006-0687-z
|View full text |Cite
|
Sign up to set email alerts
|

Evaluierung individueller, in der CAD/CAM-Technik gefertigter Bioverit®-Keramik-Implantate zur Wiederherstellung mehrdimensionaler kraniofazialer Defekte am menschlichen Schädel

Abstract: Finally, it can be stated that the preoperative expenditures in time, experts, technology and fabrication of individual CAD/CAM planned and manufactured implants are justified by the following advantages: fixed volume, reduced operating time, lack of donor morbidity, easy subsequent treatment of the material and the aesthetic results achieved.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0
3

Year Published

2008
2008
2022
2022

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 18 publications
(10 citation statements)
references
References 32 publications
0
7
0
3
Order By: Relevance
“…8 mm); (d) specific functionalizations of a middle ear prosthesis with a mesoporous silica coating, which is used for a site-specific attachment of a growth factor and for local drug delivery. [21][22][23][24][25] A typical middle ear prosthesis made from this material is shown in Fig. 1c.…”
Section: Thomas Lenarzmentioning
confidence: 99%
“…8 mm); (d) specific functionalizations of a middle ear prosthesis with a mesoporous silica coating, which is used for a site-specific attachment of a growth factor and for local drug delivery. [21][22][23][24][25] A typical middle ear prosthesis made from this material is shown in Fig. 1c.…”
Section: Thomas Lenarzmentioning
confidence: 99%
“…Just as titanium implants, the glass-ceramic Bioverit ® established in ear-surgery by Beleites et al [10] is available as an individual CAD/CAM implant for craniofacial reconstruction showing good clinical results [11], [137]. The implants allow intraoperative remodelling and adjustment with a bur and, in opposite to titanium implants, do not show thermosensitivity.…”
Section: Bone Substitutesmentioning
confidence: 99%
“…So konnte im Tierversuch eine calciumphosphatreiche Schicht zwischen Knochen und Bioverit I beobachtet werden, was für eine chemische Bindung spricht [39]. Glaskeramik-Granulat kann intraoperativ in der erforderlichen Menge eingebracht und dann mit Salzlösung gebunden werden und ist somit variabler verwendbar als Platten und Blöcke, die präoperativ zugeschnitten werden müssen [37]; allerdings sind Letztere für präoperativ anhand virtueller Modelle präformierte Implantate geeignet [40,41]. Gegenüber Titan ist die Wärmeleitung deutlich reduziert, und Artefakte in der Bildgebung werden vermieden [40].…”
Section: Titannetzeunclassified
“…a Der Navigationspointer (grün) zeigt die exakte Übereinstimmung der Oberflächen von Implantat und präoperativem Knochen (orange). b Rechts Keramik-Implantat (Bioverit II ) in situ mit Titanplatten fixiert (nach [40]).…”
Section: Nichtmetallische Implantateunclassified