2013
DOI: 10.1590/s0103-50532013000100008
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation study of an ion selective field effect transistor electrode for measuring quality parameters of fuel ethanol

Abstract: Um eletrodo íon seletivo baseado em transistor de efeito de campo (ISFET) foi avaliado na medição de pH e índice de acidez (IA) de etanol combustível e comparado a dois eletrodos de vidro contendo soluções de referência diferentes: solução aquosa de KCl (eletrodo glass-KCl) e solução etanólica de LiCl (eletrodo glass-LiCl). O pH foi determinado utilizando diferentes tempos de medição e AN foi determinado utilizando titulação potenciométrica automática. Para pH, o eletrodo glass-KCl apresentou as melhores preci… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 10 publications
(10 reference statements)
0
3
0
Order By: Relevance
“…This method requires the use of a specific electrode, includes detailed measurement constraints, and suggests traceability is achieved through calibration of the specified electrode using aqueous buffer solutions. Reports on measurement of pHe in bioethanol originate with national metrology institutes (NMIs) in Brazil [ [11] , [12] , [13] , [14] , [15] ], the EU [ [16] , [17] , [18] ], and a national research center in the USA [ 19 ]. The significant issues with the ASTM method of measuring pHe have been discussed in Brown et al [ 17 ].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…This method requires the use of a specific electrode, includes detailed measurement constraints, and suggests traceability is achieved through calibration of the specified electrode using aqueous buffer solutions. Reports on measurement of pHe in bioethanol originate with national metrology institutes (NMIs) in Brazil [ [11] , [12] , [13] , [14] , [15] ], the EU [ [16] , [17] , [18] ], and a national research center in the USA [ 19 ]. The significant issues with the ASTM method of measuring pHe have been discussed in Brown et al [ 17 ].…”
Section: Introductionmentioning
confidence: 99%
“…However, in low water content solvent mixtures, and generally in non-aqueous organic solvents, its applicability is restricted (often to the point of being useless) primarily due to: Poor performance of the commonly used glass electrodes in non-aqueous media. One of the major issues with the use of aqueous buffer calibrated glass electrodes, including those specifically marketed for the measurement of ethanol [ 11 , 14 , 15 , 23 ], is the unknown magnitude of the liquid junction potential (LJP) between the pH electrodes' reference electrode filling solution and the non-aqueous solution under test. Further, glass electrodes behave differently when in contact with aqueous solutions vs. mixed water-ethanol solutions.…”
Section: Introductionmentioning
confidence: 99%
“…Light‐addressable potentiometric sensor (LAPS), which is similar to the ion‐sensitive field‐effect transistor [1–3], is one type of surface potential sensor based on semiconductor principle [4, 5]. LAPS can be used for many biochemical measurements [6–10].…”
Section: Introductionmentioning
confidence: 99%