Evaluation of β-d-glucuronidase and particle-size distribution for microbiological water quality monitoring in Northern Vietnam

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
15
0
1

Year Published

2017
2017
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 36 publications
(17 citation statements)
references
References 34 publications
1
15
0
1
Order By: Relevance
“…They are routinely used by water utilities for real-time monitoring of source water quality and water treatment processes. Recent studies though have reported the absence or weak association between these parameters and GLUC activity (Stadler et al, 2016;Ender et al, 2017;Ryzinska-Paier et al, 2014;Stadler et al, 2010). Our results show that the relationship a Time before peak GLUC activity.…”
Section: Online B-d-glucuronidase Monitoring As Early Warning Fecal Imentioning
confidence: 99%
See 2 more Smart Citations
“…They are routinely used by water utilities for real-time monitoring of source water quality and water treatment processes. Recent studies though have reported the absence or weak association between these parameters and GLUC activity (Stadler et al, 2016;Ender et al, 2017;Ryzinska-Paier et al, 2014;Stadler et al, 2010). Our results show that the relationship a Time before peak GLUC activity.…”
Section: Online B-d-glucuronidase Monitoring As Early Warning Fecal Imentioning
confidence: 99%
“…In recent years, online technologies capable of measuring microbial parameters at high frequency (<hourly) have been developed and successfully implemented in various field settings, from source to the tap (IWA, 2018). These technologies include flow cytometry (Besmer et al, 2014;Page et al, 2017), enzymatic activity (Ender et al, 2017;Ryzinska-Paier et al, 2014;Stadler et al, 2016;Tryland et al, 2015) as well as optical and humic acid-like fluorescence (Højris et al, 2016;Sorensen et al, 2015). Enzyme-based assays specifically quantify the occurrence of fecal indicator bacteria (FIB) such as E. coli by targeting metabolic enzymes already in use in conventional culture-based assays for these bacteria.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Hathaway et al, 2014;Oliver et al, 2015). In addition, there are also emerging technologies that can monitor beta-D-glucuronidase enzymatic activity in streams in near real-time, which may have potential to provide high temporal-resolution data relating to microbial contamination that can complement more traditional means of FIO enumeration (Stadler et al, 2016;Ender et al, 2017). Exploiting these advances in the collection of higher frequency data is likely to be instrumental in permitting a more thorough evaluation of hypothesised linkages between hydrological connectivity and FIO dynamics (de Brauwere et al, 2014;Oliver et al, 2016).…”
Section: Future Prospects For Combining Fio and Tracer-aided Hydrologmentioning
confidence: 99%
“…Diese Region ist gekennzeichnet durch Karstkegelformationen mit steilen Hängen, tiefen Tälern und Gebirgshöhen bis 2 000 m +NN sowie durch subtropisches Klima mit ausgeprägten Regen‐ (Mai–Oktober) und Trockenzeiten (November–April). Neben den topografischen und klimatischen Gegebenheiten führen auch die hydrogeologischen Bedingungen dazu, dass die Bewohner unter teils erheblichem Wassermangel leiden . Denn etwa die Hälfte der Provinz besteht aus Kalkgestein, welches aufgrund seiner hohen Porosität zu einer Verlagerung des Abflussgeschehens in unterirdische Höhlensysteme führt (Bild ).…”
Section: Das Projektgebietunclassified