2012
DOI: 10.1148/radiol.12120055
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of Valvular Insufficiency and Shunts with Parallel-imaging Compressed-sensing 4D Phase-contrast MR Imaging with Stereoscopic 3D Velocity-fusion Volume-rendered Visualization

Abstract: Purpose:To assess the potential of compressed-sensing parallel-imaging four-dimensional (4D) phase-contrast magnetic resonance (MR) imaging and specialized imaging software in the evaluation of valvular insufficiency and intracardiac shunts in patients with congenital heart disease. Materials andMethods:Institutional review board approval was obtained for this HIPAAcompliant study. Thirty-four consecutive retrospectively identified patients in whom a compressed-sensing parallel-imaging 4D phase-contrast sequen… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
86
0

Year Published

2013
2013
2016
2016

Publication Types

Select...
6
1

Relationship

5
2

Authors

Journals

citations
Cited by 78 publications
(89 citation statements)
references
References 22 publications
3
86
0
Order By: Relevance
“…1,2,18,21,22,25,28,29 All of these studies found that the combined methodology produced images deemed acceptable or not significantly different from fully sampled images, while employing acceleration rates from 23 to 7.23, depending on the application. Five of these studies compared the combined method with the standard imaging protocol for the respective study's imaging application.…”
Section: Methodsmentioning
confidence: 98%
See 2 more Smart Citations
“…1,2,18,21,22,25,28,29 All of these studies found that the combined methodology produced images deemed acceptable or not significantly different from fully sampled images, while employing acceleration rates from 23 to 7.23, depending on the application. Five of these studies compared the combined method with the standard imaging protocol for the respective study's imaging application.…”
Section: Methodsmentioning
confidence: 98%
“…32 A total of 275 subjects were imaged across the 18 studies (range, 3-34; mean 5 15.28; median 5 11.5; standard deviation 5 10.23). 7 studies imaged healthy subjects, 15,[19][20][21]23,24,27 and 11 imaged patients referred for the type of imaging under consideration 1,2,14,[16][17][18]22,25,26,28,29 ( Figure 5). …”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Compressed sensing in combination with Poisson disk undersampling has also been used to accelerate 4D flow MRI, reaching net acceleration factors of 2 to 5 [109][110].…”
Section: Undersampling Of K-spacementioning
confidence: 99%
“…Other methods, such as k-t PCA or compressed sensing, have been demonstrated to achieve acceleration factors up to 8 [109][110]139]. The combination of spiral 4D flow MRI with such methods may permit even higher acceleration factors.…”
Section: Future Workmentioning
confidence: 99%