Evaluation of uterine ultrasound imaging in cervical radiotherapy; a comparison of autoscan and conventional probe

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
1
1

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 21 publications
(23 reference statements)
0
2
0
Order By: Relevance
“…Interobserver manual contour agreement : The DC, DSC, and MSSD values reported here (medians of 5.4 mm, 0.78, and 3.20 mm, respectively) are consistent with those reported in similar studies, though a direct comparison was not possible due to differences in: imaging modalities used, the disease status of the cohort investigated, the anatomical site contoured, and the number of observers. Baker et al reported a median DC of 6.0 mm between contours of two observers in manually delineating the uterus on 3D US on a healthy volunteer cohort . In the literature, reported values of the DSC between manual contours drawn on CT and MRI images for a variety of anatomical sites ranged from ∼ 0.7–0.98 with ∼ 0.7–0.8 generally considered acceptable .…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Interobserver manual contour agreement : The DC, DSC, and MSSD values reported here (medians of 5.4 mm, 0.78, and 3.20 mm, respectively) are consistent with those reported in similar studies, though a direct comparison was not possible due to differences in: imaging modalities used, the disease status of the cohort investigated, the anatomical site contoured, and the number of observers. Baker et al reported a median DC of 6.0 mm between contours of two observers in manually delineating the uterus on 3D US on a healthy volunteer cohort . In the literature, reported values of the DSC between manual contours drawn on CT and MRI images for a variety of anatomical sites ranged from ∼ 0.7–0.98 with ∼ 0.7–0.8 generally considered acceptable .…”
Section: Discussionmentioning
confidence: 99%
“…Baker et al reported a median DC of 6.0 mm between contours of two observers in manually delineating the uterus on 3D US on a healthy volunteer cohort. 36 In the literature, reported values of the DSC between manual contours drawn on CT and MRI images for a variety of anatomical sites ranged from 0.7-0.98 25,26,37,38 with 0.7-0.8 generally considered acceptable. [25][26][27] The MSSD between manual contours drawn on US, CT, and MRI images reported in the literature for a variety of anatomical sites ranged from 1-5 mm.…”
Section: Discussionmentioning
confidence: 99%