2007
DOI: 10.1002/jps.20827
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of tunable diode laser absorption spectroscopy for in‐process water vapor mass flux measurements during freeze drying

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
73
0

Year Published

2008
2008
2022
2022

Publication Types

Select...
5
4
1

Relationship

1
9

Authors

Journals

citations
Cited by 133 publications
(74 citation statements)
references
References 10 publications
1
73
0
Order By: Relevance
“…The Doppler-shifted near-infrared absorption spectroscopy is used for measuring the water vapour concentration and gas flow velocity in the duct (that connects drying and condenser chamber). At this point, these variables can be used, known the cross-sectional area of the duct, to estimate the vapour flow rate (Kessler et al, 2006;Gieseler et al, 2007). It must be remarked that TDLAS does not measure directly the mass flow, but only the gas flow velocity in a limited number of points; therefore, the reliability of the vapour flow rate estimation depends on how well the velocity profile is known.…”
Section: Experimental Methods For K V Measurementmentioning
confidence: 99%
“…The Doppler-shifted near-infrared absorption spectroscopy is used for measuring the water vapour concentration and gas flow velocity in the duct (that connects drying and condenser chamber). At this point, these variables can be used, known the cross-sectional area of the duct, to estimate the vapour flow rate (Kessler et al, 2006;Gieseler et al, 2007). It must be remarked that TDLAS does not measure directly the mass flow, but only the gas flow velocity in a limited number of points; therefore, the reliability of the vapour flow rate estimation depends on how well the velocity profile is known.…”
Section: Experimental Methods For K V Measurementmentioning
confidence: 99%
“…The easiest way to measure the mass flow rate at the choke point is by tunable diode laser absorption spectroscopy (10) or TDLAS (see discussion below). Where TDLAS is not available, the mass flow rate corresponding to choked flow can be measured gravimetrically after stopping the process at a point where most of the initial ice load remains.…”
Section: The Capacitance Manometermentioning
confidence: 99%
“…Then, model parameters (Kv and Rp), as well as other variables like product temperature and the residual amount of ice, are estimated looking for the best fit between the values of chamber pressure measured and those calculated using a mathematical model of the process [22][23][24][25][26][27]. As an alternative to this method, it is possible to use Tunable Diode Laser Absorption Spectroscopy (TDLAS) to estimate Kv and Rp, beside product temperature and the residual amount of ice [28][29][30]. Moreover, a soft-sensor based on the measurement of product temperature, on a mathematical model of the process and on the Extended Kalman Filter algorithm was also proposed to get the values of Kv and Rp [31][32][33][34][35][36][37].…”
Section: Introductionmentioning
confidence: 99%