2020
DOI: 10.1007/s00330-020-07193-x
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of trigeminal nerve tractography using two-fold-accelerated simultaneous multi-slice readout-segmented echo planar diffusion tensor imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
2
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 40 publications
0
2
0
Order By: Relevance
“…Then, deterministic fiber tracking ( Mori et al, 1999 ) was carried out to reconstruct the whole brain fibers, using the Fiber Assignment by Continuous Tracking (FACT) algorithm. If the angle between the current and the previous streamline was greater than 45° ( Li et al, 2013 ) or the FA value smaller than 0.2 ( Koh et al, 2020 ), the current streamline tracking procedure was terminated. The orientation patch was achieved by inverting the Z component of the vector.…”
Section: Methodsmentioning
confidence: 99%
“…Then, deterministic fiber tracking ( Mori et al, 1999 ) was carried out to reconstruct the whole brain fibers, using the Fiber Assignment by Continuous Tracking (FACT) algorithm. If the angle between the current and the previous streamline was greater than 45° ( Li et al, 2013 ) or the FA value smaller than 0.2 ( Koh et al, 2020 ), the current streamline tracking procedure was terminated. The orientation patch was achieved by inverting the Z component of the vector.…”
Section: Methodsmentioning
confidence: 99%
“…Diffusion tensor imaging, a technique based on the principle of diffusion motion of water protons in nerve tissue, has recently received attention in TN studies. Several studies support the use of DTI in TN for its ability to expose the CNV at a microstructure level 8 , 15 , 19 , 31 37 . DTI has been used to evaluate the efficacy of MVD and gamma knife radiosurgery (GKRS) with the REZ for TN as the therapeutic target 12 , 20 , 22 .…”
Section: Discussionmentioning
confidence: 93%
“…Corrections need to be made by increasing the scan time, which limits its use in the body. 15,18 To ensure sufficient image quality, we reduced the acquisition time of Rs-EPI as much as possible while maintaining a good model fit. Both Liney 19 and Klingebiel et al 15 have shown that Rs-EPI is superior to conventional ss-EPI with better image quality.…”
Section: Discussionmentioning
confidence: 99%
“…Motion‐induced phase changes during diffusion‐encoded gradients lead to deformation of the image domain between readout segments. Corrections need to be made by increasing the scan time, which limits its use in the body 15,18 . To ensure sufficient image quality, we reduced the acquisition time of Rs‐EPI as much as possible while maintaining a good model fit.…”
Section: Discussionmentioning
confidence: 99%