Evaluation of the Tasso-SST® capillary blood microsampling device for the measurement of endogenous uracil levels

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 14 publications
0
3
0
Order By: Relevance
“…The widely evaluated Tasso-SST device collects ~300 µL whole blood [1,[8][9][10][11] into a tube that contains a clot activator and separation gel but is no longer available [12]. To date, these devices have been assessed for clinical chemistry [3,4,[13][14][15], haematology [2], and serology [8][9][10][11][16][17][18], with overall good analytical performance and participant acceptance. It must be noted, however, that most automated analysers require a dead volume (200-300 µL) of specimen in addition to the volume required for analyte testing.…”
Section: Introductionmentioning
confidence: 99%
“…The widely evaluated Tasso-SST device collects ~300 µL whole blood [1,[8][9][10][11] into a tube that contains a clot activator and separation gel but is no longer available [12]. To date, these devices have been assessed for clinical chemistry [3,4,[13][14][15], haematology [2], and serology [8][9][10][11][16][17][18], with overall good analytical performance and participant acceptance. It must be noted, however, that most automated analysers require a dead volume (200-300 µL) of specimen in addition to the volume required for analyte testing.…”
Section: Introductionmentioning
confidence: 99%
“…Microsampling technologies have been evaluated in biomarker research studies for the diagnosis and prognosis of various conditions and the prediction and monitoring of response to an intervention 24,41,42,132–144 . Omics‐based approaches, such as metabolomics and proteomics, are increasingly employed for the generation of large amounts of data to facilitate the rapid discovery of biomarkers.…”
Section: Applicationsmentioning
confidence: 99%
“…However, at‐home sampling using TASSO‐SST for uracil measurements is not feasible due to the compound's high instability. Nevertheless, microsampling technology can be implemented at the hospital to reduce the burden of repeated blood draws in cancer patients 137 . A randomised, control trial evaluated the accuracy, feasibility and acceptability of microsampling techniques in rheumatoid arthritis patients by measuring inflammation markers and autoantibodies in three matrices: conventional venous blood, upper arm capillary blood obtained using TASSO‐SST and finger prick capillary blood.…”
Section: Applicationsmentioning
confidence: 99%