2002
DOI: 10.1002/col.10061
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of the quality of different D65 simulators for visual assessment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
12
0

Year Published

2003
2003
2019
2019

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 20 publications
(14 citation statements)
references
References 23 publications
1
12
0
Order By: Relevance
“…The CIE chromaticity coordinates of this sample were found to be (0.3165,0.3270), and its CCT value was 6313.4 K, which is also located in the bluish‐white‐light region. This position is very close to that of the D65 illuminant, for which the CIE coordinates are (0.3127, 0.3290) . Therefore, the phosphor has potential application as a noon daylight simulator as its white‐light emission has comparable CIE chromaticity coordinates and CCT with that of the noon daylight …”
Section: Resultsmentioning
confidence: 57%
“…The CIE chromaticity coordinates of this sample were found to be (0.3165,0.3270), and its CCT value was 6313.4 K, which is also located in the bluish‐white‐light region. This position is very close to that of the D65 illuminant, for which the CIE coordinates are (0.3127, 0.3290) . Therefore, the phosphor has potential application as a noon daylight simulator as its white‐light emission has comparable CIE chromaticity coordinates and CCT with that of the noon daylight …”
Section: Resultsmentioning
confidence: 57%
“…D 50 (CCT 5000K) and D 65 (CCT 6504K) light sources are used to simulate daylight. Therefore, the D 65 light source, which represents the average daylight in the northern hemisphere, is used as standard light source for international color evaluation . F 2 , F 11 , and F 12 light sources are fluorescent lamps with discontinuous spectral power distribution to release a small amount of fluorescence.…”
Section: Methodsmentioning
confidence: 99%
“…Visual assessment, employing a wide range of practical metamers and simulators, is a straightforward approach to achieve this objective. A recent study conducted by Lam and Xin reported the evaluation of five daylight simulators using metameric sample pairs [21]. Their results indicated that better agreement between instrumental and visual colour differences was obtained using the SPD of a D65 simulator than using the SPD of the D65 illuminant itself.…”
Section: Cie Metamerism Index Methodsmentioning
confidence: 99%
“…All the observers were assessed using the Ishihara test and found to have normal colour vision. The grey scale method, which has been extensively used by many researchers [21][22]25,26], was used in the experiment. The whole experiment was conducted using a viewing cabinet located in a dark room.…”
Section: Psychophysical Experimentsmentioning
confidence: 99%