2014
DOI: 10.1007/s12046-014-0235-8
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of the main parameters affecting seismic performance of the RC buildings

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0
2

Year Published

2015
2015
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 23 publications
(9 citation statements)
references
References 6 publications
0
7
0
2
Order By: Relevance
“…The height of a building can influence its seismic performance. Generally speaking, low-hight buildings are considered seismically less vulnerable [45]. Two types of height ranges are considered in this latest RVS procedure of FEMA: 1-3 stories and more than 3 stories; however, the modification score for building height is applicable only if a building is located on the soil type E. Building height does not greatly influence seismic performance, and therefore its score modifier is applicable only to soft soil (type E).…”
Section: Building Heightmentioning
confidence: 99%
“…The height of a building can influence its seismic performance. Generally speaking, low-hight buildings are considered seismically less vulnerable [45]. Two types of height ranges are considered in this latest RVS procedure of FEMA: 1-3 stories and more than 3 stories; however, the modification score for building height is applicable only if a building is located on the soil type E. Building height does not greatly influence seismic performance, and therefore its score modifier is applicable only to soft soil (type E).…”
Section: Building Heightmentioning
confidence: 99%
“…Za gredu je primijenjen i zahtjev u pogledu minimalne širine. Usvojena je visina u iznosu od 50 cm, što je prema [35,36] uobičajena vrijednost koja se koristi u praksi. Kako je presjek grede obično konstantan, te kako se u analizama uzimala u obzir samo krutost zidane ispune (neubrojivši krutost praznog okvira), u matrici analize korišteni su isti presjeci i za stupove i za grede.…”
Section: Slika 1 Izgled Modela Bez Deformacija (Gore) I S Deformacijunclassified
“…Poznato je da se rasponi u nekoj građevini mogu međusobno bitno razlikovati. Prema radovima koje su prikazali Hancilar i dr. [35] i Ozmen i dr. [36], rasponi mogu po duljini varirati od 3,0 metra do 8,0 metara. Stoga je za analizu metodom konačnih elemenata odabrano šest različitih ravninskih armiranobetonskih okvira, kao što je prikazano u tablici 2.…”
Section: Matrica Analizeunclassified
“…As aforementioned, there are many studies using AVM methods to evaluate building dynamic characteristics in the literature. However, as the regional construction practices affect the building properties, the reported values from different regions are important to enrich the current literature [27]. Additionally, it is stated in the literature that in situ measurement of full-scale partially damaged structures is of considerable interest [3].…”
Section: Introductionmentioning
confidence: 99%