2020
DOI: 10.1167/tvst.9.12.19
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of the IOP-Lowering Effect of a Multi-Pressure Dial at Different Negative Pressure Settings

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

7
25
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 13 publications
(32 citation statements)
references
References 19 publications
7
25
0
Order By: Relevance
“…Further, there was no evidence of rebound IOP spikes following the application of negative pressure across all test runs. The results of this study confirm that controlled application of periocular negative pressure leads to a reduction in IOP, supporting the results of prior clinical studies [6,7,10] that reported a reduction in IOP with the MPD system. Collectively, Fig.…”
Section: Discussionsupporting
confidence: 89%
See 1 more Smart Citation
“…Further, there was no evidence of rebound IOP spikes following the application of negative pressure across all test runs. The results of this study confirm that controlled application of periocular negative pressure leads to a reduction in IOP, supporting the results of prior clinical studies [6,7,10] that reported a reduction in IOP with the MPD system. Collectively, Fig.…”
Section: Discussionsupporting
confidence: 89%
“…Given that the changes in RBP fell below the range of uncertainty in both subjects, we concluded there was no detectable change in RBP with application of negative pressure across all test runs. Multiple prior studies have investigated the IOP-lowering ability of the MPD in both healthy and glaucomatous eyes as measured via the excursion test method, a developed technique for IOP measurement that involves a pneumatonometer across a tonometer tip cover (Tono-penÒ; Reichert Technologies, Buffalo, New York) with a specially adapted version of the MPD goggles [6,7,10]. In a recent study in 65 healthy subjects, Swan et al [6] used three different negative pressure settings, namely 25, 50 and 75% of baseline IOP, and demonstrated a stepwise increase in IOP reduction with increased levels of negative pressure.…”
Section: Discussionmentioning
confidence: 99%
“…In this study, an IOP reduction was also observed in the contralateral, or control eye. Although a minor reduction, this has not been demonstrated in prior studies evaluating the IOP-lowering ability of the device [22,24] and suggests future investigation is warranted evaluating the IOP-lowering ability of the MPD in the nocturnal setting and/or supine position.…”
Section: Discussionmentioning
confidence: 81%
“…The MPD, a novel device currently under investigation, decreases IOP by modulation of atmospheric pressure in a localized, enclosed microenvironment immediately anterior and external to the patient’s eye. With prior work 10 , 13 establishing the IOP-lowering benefit of the device with direct application of negative pressure (e.g. patient awake with eyelids open) to the cornea, this study aimed to investigate with a model whether a mitigation in negative pressure application occurs when applied through tissue (e.g.…”
Section: Discussionmentioning
confidence: 99%
“…Prior work in healthy subjects has demonstrated the titratable IOP-lowering capability of the device at various negative pressure test settings. 10 However, it remains unclear whether the eyelids, when closed, affect the IOP-lowering mechanism created by the localized negative pressure microenvironment. Transmission of negative pressure through a closed eyelid would enable patients to use the therapy while sleeping.…”
Section: Introductionmentioning
confidence: 99%