2016
DOI: 10.1016/j.scp.2016.10.003
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of the inhibitive effect of Diospyros kaki (Persimmon) leaves extract on St37 steel corrosion in acid medium

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
20
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 52 publications
(21 citation statements)
references
References 43 publications
1
20
0
Order By: Relevance
“…E a can be calculated using Arrhenius Equation 81,82 :where CR stands for the corrosion rate at a temperature (T) which is expressed by the corrosion current density ( i ), E a represents the apparent activation energy and A is the Arrhenius constant that depends on the metal type and electrolyte. R is the universal gas constant (8.314 J mol −1 K −1 ).…”
Section: Resultsmentioning
confidence: 99%
“…E a can be calculated using Arrhenius Equation 81,82 :where CR stands for the corrosion rate at a temperature (T) which is expressed by the corrosion current density ( i ), E a represents the apparent activation energy and A is the Arrhenius constant that depends on the metal type and electrolyte. R is the universal gas constant (8.314 J mol −1 K −1 ).…”
Section: Resultsmentioning
confidence: 99%
“…The corresponding electrical equivalent circuits, along with the related fitted parameters for the initial and long-term immersion, are shown in Figure 13a,b, respectively. The fitted parameters include the following factors: R1-solution resistance, R2 and Q1 (capacitor), related to the double layer [19,20], R3 and Q2, corresponding to charge transfer resistance and capacitor, respectively, which are related to the effect of corrosion products and the time constant that appeared in the low frequency region [21,22]. Stress corrosion examination of the printed ER70S-6 and reference ST-37 alloys by slow strain rate testing (SSRT) in 3.5% NaCl solution in terms of UTS and elongation are shown in Figures 14 and 15, respectively.…”
Section: Resultsmentioning
confidence: 99%
“…The related electrical equivalent circuit, as well as the fitted parameters, are shown in Figure 6. The fitted parameters were: R1, solution resistance; R2 and C1 represent the double layer [29]; R3 and C2 represent the charge transfer resistance and capacitor [30].…”
Section: Am Er70s-6mentioning
confidence: 99%
“…The related electrical equivalent circuit, as well as the fitted parameters, are shown in Figure 6. The fitted parameters were: R1, solution resistance; R2 and C1 represent the double layer [29]; R3 and C2 represent the charge transfer resistance and capacitor [30]. The high cycle fatigue strengths of additively manufactured ER70S-6 alloy and its counterpart ST-37 alloy, in air and in 3.5% NaCl solution, in terms of their S-N curves, are shown in Figure 7a,b.…”
Section: Am Er70s-6mentioning
confidence: 99%