2012
DOI: 10.1118/1.4752211
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of the Gafchromic® EBT2 film for the dosimetry of radiosurgical beams

Abstract: This work found that the Gafchromic(®) EBT2 film is adequate for small photon beam measurements, particularly for tissue maximum and off-axis ratios. However, careful attention must be taken when measuring output factors of small beams below 1.0 cm due to the film's energy dependence. The measurement differences may be attributable to the film's active layer composition because EBT2 incorporates higher Z elements (i.e., bromide and potassium), hence revealing a potential energy dependence for the dosimetry of … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
20
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 20 publications
(20 citation statements)
references
References 29 publications
(36 reference statements)
0
20
0
Order By: Relevance
“…The microLion has been discontinued by manufacturer and is not available commercially. For the Gafchromic EBT2/3 films, proper precautions and experience is needed for achieve comparable data (59)(60)(61). User should also evaluate the criterion for correction-less dosimetry if there is any doubt as discussed by Kamio and Bouchard (57).…”
Section: Discussionmentioning
confidence: 99%
“…The microLion has been discontinued by manufacturer and is not available commercially. For the Gafchromic EBT2/3 films, proper precautions and experience is needed for achieve comparable data (59)(60)(61). User should also evaluate the criterion for correction-less dosimetry if there is any doubt as discussed by Kamio and Bouchard (57).…”
Section: Discussionmentioning
confidence: 99%
“…A range of detectors broadly categorized into active (ionization chambers, solid state detectors, and plastic scintillator) and passive (TLD microcubes, gafchromic film, alanine pallets, radio photoluminescent dosimeter, and gel dosimeter) detectors have been investigated by numerous authors for small field measurements. [9101112131415161718192021222324]…”
Section: Introductionmentioning
confidence: 99%
“…[123456789] However, the process is cumbersome when an absorbed dose is measured using radiochromic film as a film dosimeter, and it is necessary for the film density to be converted into an absorbed dose. For general measurement, time-scale methods requiring several dozen irradiations were performed.…”
Section: Introductionmentioning
confidence: 99%