2016
DOI: 10.17159/2309-8309/2016/v15n1a7
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of the first experience of intramedullary nail lengthening using PRECICE® in a South African limb lengthening and reconstruction unit

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
4
0
1

Year Published

2017
2017
2022
2022

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 23 publications
0
4
0
1
Order By: Relevance
“…A few case-control studies have compared these nails with external fixation (13–15 patients), and the largest case series on intramedullary bone lengthening reports on 92 patients (Black et al 2015 , Horn et al 2015 , Calder et al 2019 ). However, the majority of reports of complications of the FITBONE and PRECICE lengthening nails are small case series (Krieg et al 2008 , Dinçyürek et al 2012 , Birkholtz and De-Lange 2016 , Hammouda et al 2017 ). In recent years motorized intramedullary lengthening nails have become increasingly popular, and we thus hypothesized that standardized data on complications could now be extracted from the literature.…”
mentioning
confidence: 99%
“…A few case-control studies have compared these nails with external fixation (13–15 patients), and the largest case series on intramedullary bone lengthening reports on 92 patients (Black et al 2015 , Horn et al 2015 , Calder et al 2019 ). However, the majority of reports of complications of the FITBONE and PRECICE lengthening nails are small case series (Krieg et al 2008 , Dinçyürek et al 2012 , Birkholtz and De-Lange 2016 , Hammouda et al 2017 ). In recent years motorized intramedullary lengthening nails have become increasingly popular, and we thus hypothesized that standardized data on complications could now be extracted from the literature.…”
mentioning
confidence: 99%
“…Birkholtz y colaboradores 22 describieron su experiencia inicial con el clavo Precice ® en nueve pacientes, con resultados similares a los nuestros, objetivando un alargamiento promedio de 45 mm y una precisión de 103%, registrando un total de dos complicaciones. En nuestro estudio encontramos un total de cuatro problemas que se solucionaron con tratamiento conservador, sin registrar ninguna complicación que necesitase de intervención quirúrgica.…”
Section: Discussionunclassified
“…[10,11] The PRECICE nail system is available in different lengths, diameters, strokes, angulations, and entry points. [12,13] These features accommodate for various needs and challenges that one might face in clinical practice. Although this versatility is useful to utilize, tailoring these various features can present quite a challenge in itself.…”
mentioning
confidence: 99%
“…It is important to note that distraction osteogenesis through a fixator applied externally is an established technique for lower limb lengthening. [13][14][15] However, these treatments have had high complication rates, amounting to at most 3.2 complications per patient. [16,17] The pins or wires that penetrate the soft tissues trigger such complications as pain, pin-site infection, muscle transfixation, immobility, reduced joint movement, and scarring.…”
mentioning
confidence: 99%
See 1 more Smart Citation