2018
DOI: 10.31661/jbpe.v8i1mar.697
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of the Effect of Source Geometry on the Output of Miniature X-ray Tube for Electronic Brachytherapy through Simulation

Abstract: Objective: The use of miniature X-ray source in electronic brachytherapy is on the rise so there is an urgent need to acquire more knowledge on X-ray spectrum production and distribution by a dose. The aim of this research was to investigate the influence of target thickness and geometry at the source of miniature X-ray tube on tube output. Method:Five sources were simulated based on problems each with a specific geometric structure and conditions using MCNPX code. Tallies proportional to the output were used … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 30 publications
(33 reference statements)
0
2
0
Order By: Relevance
“…In this study, hemispherical-conical, hemispherical, and truncated-conical miniature X-ray tubes [6,8] simulated with the Monte Carlo code MCNPX (2.6.0) were used (Figure 1). In these simulations, the densities of tungsten, beryllium, and water were 19.3, 1.84, and 0.998 g/cm 3 according to the Reference [7], and the density of the carbon layer was 1.35 gr/cm 3 according to the Reference [8,9].…”
Section: Simulation Of Miniature X-ray Tubes and The Mcnp Codementioning
confidence: 99%
See 1 more Smart Citation
“…In this study, hemispherical-conical, hemispherical, and truncated-conical miniature X-ray tubes [6,8] simulated with the Monte Carlo code MCNPX (2.6.0) were used (Figure 1). In these simulations, the densities of tungsten, beryllium, and water were 19.3, 1.84, and 0.998 g/cm 3 according to the Reference [7], and the density of the carbon layer was 1.35 gr/cm 3 according to the Reference [8,9].…”
Section: Simulation Of Miniature X-ray Tubes and The Mcnp Codementioning
confidence: 99%
“…In the mid-1950s, replacing cold cathodes with hot cathodes was suggested to overcome the disadvantages of hot cathodes [5]. Accordingly, the X-ray production using the field emission method was first reported in 1956 [6]. The necessary equations and explanations in this field are given in Appendix 2 [7].…”
Section: Introductionmentioning
confidence: 99%