1964
DOI: 10.1111/j.1365-2621.1964.tb01713.x
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of the Biuret and Dye‐Binding Methods for Protein Determination in Meats

Abstract: SUMMARY The biuret method of protein estimation was compared with the Kjeldahl method. Highly significant positive correlations with Kjeldahl protein of 0.99, 0.99, 0.98, and 0.99 were obtained for ground beef, pork, chicken breast, and cod, respectively. The high correlations between the two methods and the small standard deviations for the biuret values point out the reliability and the accuracy of the biuret method. The same substances were analyzed by the Orange G dye‐binding method with highly significant… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
48
0

Year Published

1974
1974
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 116 publications
(51 citation statements)
references
References 11 publications
0
48
0
Order By: Relevance
“…Protein concentrations in all mixed protein solutions as well as in column-separated fractions (described below) were determined by the biuret method. 15 After inactivation of the enzymes (80 • C for 20 min) the hydrolysates were freeze-dried for later separation. The resulting degrees of hydrolysis for W/A, W/P and W/F were 0.15, 0.075 and 0.2 g ml −1 respectively.…”
Section: Materials and Methods Wpi Hydrolysatesmentioning
confidence: 99%
“…Protein concentrations in all mixed protein solutions as well as in column-separated fractions (described below) were determined by the biuret method. 15 After inactivation of the enzymes (80 • C for 20 min) the hydrolysates were freeze-dried for later separation. The resulting degrees of hydrolysis for W/A, W/P and W/F were 0.15, 0.075 and 0.2 g ml −1 respectively.…”
Section: Materials and Methods Wpi Hydrolysatesmentioning
confidence: 99%
“…The mixture was homogenised in an Ultra-Turrax homogenizer (Kika Labortechnik, T25 basic, Staufen, Germany) for 65 s. The homogenate was centrifuged at 0-5°C for 15 min at 10,000Âg by using an Avanti Centrifuge J-20 XPI (Rotor 10, Beckman Coulter, Fullerton, California (CA), 92834, USA). Protein concentration of the supernatants was determined using the Biuret method (Torten & Whitaker, 1964). The standard curve was determined with various known concentrations of bovine serum albumen (BSA, Fraction V, Approx.…”
Section: Salt Soluble Proteins (Ssp)mentioning
confidence: 99%
“…The total protein content of both the raw material and final protein isolates from different solubilization methods was estimated by the Biuret procedure [14,17]. Meat sample (1 g) was dispersed in 20 mL of 0.5 M NaOH, heated in the boiling water for 10 min and cooled in an ice-water bath.…”
Section: Total Protein Content and Recovery Yieldmentioning