Evaluation of the BD Max Enteric Parasite Panel for Clinical Diagnostics

Abstract: We compared the performance of the BD Max enteric parasite panel to routine microscopy and an in-house PCR for the detection of Giardia intestinalis, Entamoeba histolytica, and Cryptosporidium spp. The enteric parasite panel showed good specificity for all targets and good sensitivity for E. histolytica and Cryptosporidium spp. Sensitivity for G. intestinalis with the BD Max enteric parasite panel was equivalent to that with microscopy. The World Health Organization (WHO) ranks diarrheal disease the second mos… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 23 publications
(5 citation statements)
references
References 17 publications
0
5
0
Order By: Relevance
“…The multiplex PCR assay Allplex TM GIPPA showed excellent performances for protozoa detection, even higher than that of other marketed PCR assays such as the BD Max TM Enteric Parasite Panel, G-DiaPara TM , or ParaGENIE G-Amoeba assays [9][10][11][12] and with additional targets. Indeed, the sensitivity of these assays ranged from 41% to 96% for G. duodenalis [9][10][11], depending on the extraction method and the assay, and the ParaGENIE G-Amoeba assay had 67% sensitivity for E. histolytica detection [12]. Moreover, the BD Max TM and G-DiaPara TM assays detected only C. parvum/hominis, and none of these detected C. cayetanensis, D. fragilis, or B. hominis.…”
Section: Discussionmentioning
confidence: 91%
“…The multiplex PCR assay Allplex TM GIPPA showed excellent performances for protozoa detection, even higher than that of other marketed PCR assays such as the BD Max TM Enteric Parasite Panel, G-DiaPara TM , or ParaGENIE G-Amoeba assays [9][10][11][12] and with additional targets. Indeed, the sensitivity of these assays ranged from 41% to 96% for G. duodenalis [9][10][11], depending on the extraction method and the assay, and the ParaGENIE G-Amoeba assay had 67% sensitivity for E. histolytica detection [12]. Moreover, the BD Max TM and G-DiaPara TM assays detected only C. parvum/hominis, and none of these detected C. cayetanensis, D. fragilis, or B. hominis.…”
Section: Discussionmentioning
confidence: 91%
“…A recent study (23) compared the BD Max EPP to microscopy and to a lab-developed PCR assay for a small set of clinical samples. The sensitivity for G.…”
Section: Discussionmentioning
confidence: 99%
“…With GenMark, for instance, pathogen detection involves ferrocene-labeled oligonucleotide probes, which associate with electrodes via amplicon-probe annealing events, altering impedance in a measurable way (as detailed below). Other major manufactures offering syndromic panels include: the FilmArray by BioFire (parent company bioMerieux), which utilizes nested PCR in sequential microreservoirs, with downstream fluorescence-detection on a 2D grid [11,13,17,18,25,26]; the VERIGENE by Luminex, which detects amplicons through gold/silver-conjugated oligonucleotide probes and an evanescent field phenomenon [17,18,26]; the xTAG and NxTAG flow cytometry systems, also by Luminex, which employ fluorescently barcoded microbeads to target amplicons [12,26,27]; the BD MAX system by BD, a qPCR platform that enables multiplexing through automated robotics [28,29]; and the T2Dx platform by T2 Biosystems, which utilizes NMR relaxometery to detect amplicon-mediated agglomeration of capture probes [19,21]. Additional technical details and performance characteristics of these platforms are detailed in the respective citations.…”