Evaluation of the automated LIAISON® SARS-CoV-2 TrimericS IgG assay for the detection of circulating antibodies

Abstract: Objectives COVID-19 has brought about tests from many manufacturers. While molecular and rapid antigen tests are targeted for early diagnosis, immunoassays have a larger role in epidemiological studies, understanding longitudinal immunity, and in vaccine development and response. Methods The performance of the LIAISON® SARS-CoV-2 TrimericS IgG assay was evaluated against the Beckman ACCESS SARS-CoV-2 IgG assay in New Mexico, … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

4
79
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 67 publications
(85 citation statements)
references
References 19 publications
4
79
1
Order By: Relevance
“…In the report evaluating two Roche anti‐SARS‐CoV‐2 assays against N or S simultaneously, 19 anti‐SARS‐CoV‐2 S showed higher sensitivity than anti‐SARS‐CoV‐2 (against N) (93.0% vs. 89.0%). In a recent report, the sensitivity of DiaSorin anti‐SARS‐CoV‐2 Trimeric S was 99.4%, which was higher than the previous version of DiaSorin anti‐SARS‐CoV‐2 against S1/S2 21 . In our study, the sensitivity was highest in Roche S and Abbott Quant (96.0%), followed by DiaSorin Trimeric S (93.6%).…”
Section: Discussioncontrasting
confidence: 71%
“…In the report evaluating two Roche anti‐SARS‐CoV‐2 assays against N or S simultaneously, 19 anti‐SARS‐CoV‐2 S showed higher sensitivity than anti‐SARS‐CoV‐2 (against N) (93.0% vs. 89.0%). In a recent report, the sensitivity of DiaSorin anti‐SARS‐CoV‐2 Trimeric S was 99.4%, which was higher than the previous version of DiaSorin anti‐SARS‐CoV‐2 against S1/S2 21 . In our study, the sensitivity was highest in Roche S and Abbott Quant (96.0%), followed by DiaSorin Trimeric S (93.6%).…”
Section: Discussioncontrasting
confidence: 71%
“…Sera were stored at − 20 °C and tested using the LIAISON® SARS-CoV-2 TrimericS IgG assay (DiaSorin S.p.A., Saluggia, Italy), an indirect chemiluminescence immunoassay (CLIA) technology for the detection of serum IgG antibodies to SARS-CoV-2 trimeric spike protein (anti-TSP IgG), including neutralizing antibodies [ 6 ]. Performance and interpretation of results were done in accordance with the manufacturer’s instructions, and the IgG titers were expressed in Binding Antibody Units (BAU), an international standard unit, with 33.8 BAU/mL as cut-off value [ 7 ].…”
Section: Methodsmentioning
confidence: 99%
“…Sera were tested at virology laboratory of our University Hospital, using the LIAISON® SARS-CoV-2 TrimericS-IgG assay (DiaSorin-S.p.A.), for the detection of IgG antibodies to SARS-CoV-2 spike protein, including neutralizing antibodies. 11 The IgG titers were expressed in binding antibody units (BAU), with 33.8 BAU/mL as negative/positive cut-off. 12 …”
mentioning
confidence: 99%