Evaluation of the accuracy and reliability for photoplethysmography based heart rate and beat-to-beat detection during daily activities

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

5
32
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
8
1
1

Relationship

0
10

Authors

Journals

citations
Cited by 46 publications
(37 citation statements)
references
References 4 publications
5
32
0
Order By: Relevance
“…The accuracy of the E4 wristband has been assessed by only a few preliminary studies, mainly focused on stress and emotion recognition (e.g., Ragot, Martin, Em, Pallamin, & Diverrez, 2017). Two studies focused on the PPG signal and suggested satisfactory data quality (McCarthy, Pradhan, Redpath, & Adler, 2016) and acceptable measurement error in mean HR and some HRV measures (Pietilä et al, 2017). However, high data quality was achieved only in conditions involving no hand movements, whereas motion artifacts represent exactly the kind of error an ambulatory sensor is expected to manage.…”
mentioning
confidence: 99%
“…The accuracy of the E4 wristband has been assessed by only a few preliminary studies, mainly focused on stress and emotion recognition (e.g., Ragot, Martin, Em, Pallamin, & Diverrez, 2017). Two studies focused on the PPG signal and suggested satisfactory data quality (McCarthy, Pradhan, Redpath, & Adler, 2016) and acceptable measurement error in mean HR and some HRV measures (Pietilä et al, 2017). However, high data quality was achieved only in conditions involving no hand movements, whereas motion artifacts represent exactly the kind of error an ambulatory sensor is expected to manage.…”
mentioning
confidence: 99%
“…It has been shown previously that IBI extracted from PPG corresponds closely with IBI extracted from ECG [67], [68]. This allowed us to exploit existing high-quality ECG datasets for this study.…”
Section: Discussionmentioning
confidence: 57%
“…e study concludes that wrist-worn devices such as the E4 are accurate and reliable for heart rate detection when hand movement is not excessive [47]. e use of a wrist-worn monitoring device, specifically the Empatica E4 at 64 Hz sample rate, is deemed sufficient for this study, since the participants are supposed to be sitting down with only moderate movement.…”
Section: Heart Rate Datamentioning