2022
DOI: 10.1149/2162-8777/ac71ca
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of Structural and Optical Properties of Nanocrystalline Cubic Y2O3 Phase Materials via Combustion Method Using Different Fuels

Abstract: We have carried out combustion synthesis of nanocrystalline Y2O3 materials using hexamine, polyethylene glycol(200) (PEG(200)), and ethylene glycol (EG) as fuels. In addition, the impact of mechanical stirring of commercial Y2O3 powder with various dilutions of PEG(200) with distilled water as a solvent was also examined. The as-prepared combustion product of the hexamine is significantly different from other fuels (PEG(200) and EG). The annealed combustion products crystallize in the pure cubic Y2O3 phase. Th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 62 publications
(151 reference statements)
0
6
0
Order By: Relevance
“…The UV-Vis-NIR spectral features of different Cr 2 O 3 samples were measured in both absorbance and reflectance modes in the instrument JASCO spectrophotometer using the light source of D2/WI. [37][38][39] The FT-IR spectral features of the samples were scanned in the FT-IR spectrometer (Nicolet iS50/Thermo Fisher Scientific) in transmittance ATR mode. 38,39 The Raman spectra were scanned in the range 80 to 1000 cm −1 using He-Ne as a laser source (632.8 nm) in the Horiba Jobin-Yvon LabRam HR800 spectrometer.…”
Section: Experimental and Characterization Techniquesmentioning
confidence: 99%
See 4 more Smart Citations
“…The UV-Vis-NIR spectral features of different Cr 2 O 3 samples were measured in both absorbance and reflectance modes in the instrument JASCO spectrophotometer using the light source of D2/WI. [37][38][39] The FT-IR spectral features of the samples were scanned in the FT-IR spectrometer (Nicolet iS50/Thermo Fisher Scientific) in transmittance ATR mode. 38,39 The Raman spectra were scanned in the range 80 to 1000 cm −1 using He-Ne as a laser source (632.8 nm) in the Horiba Jobin-Yvon LabRam HR800 spectrometer.…”
Section: Experimental and Characterization Techniquesmentioning
confidence: 99%
“…[37][38][39] The FT-IR spectral features of the samples were scanned in the FT-IR spectrometer (Nicolet iS50/Thermo Fisher Scientific) in transmittance ATR mode. 38,39 The Raman spectra were scanned in the range 80 to 1000 cm −1 using He-Ne as a laser source (632.8 nm) in the Horiba Jobin-Yvon LabRam HR800 spectrometer. [37][38][39] The micro-images (FESEM) and elemental analysis (EDX) of the Cr 2 O 3 phase nanomaterials were taken from the Inspect F FESEM equipment.…”
Section: Experimental and Characterization Techniquesmentioning
confidence: 99%
See 3 more Smart Citations