2011
DOI: 10.1007/978-3-8348-8259-2
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of State-of-the-Art Hardware Architectures for Fast Cone-Beam CT Reconstruction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0

Year Published

2013
2013
2019
2019

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 12 publications
(10 citation statements)
references
References 10 publications
0
10
0
Order By: Relevance
“…Implementation of cosine weighting follows from equations (15)- (17). Following the convolution theorem, the one-dimensional filtration of each radiograph (equation (18)) is performed in the frequency domain [17]. First, the one-dimensional fast Fourier transform (FFT) of each row in the radiograph is calculated.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Implementation of cosine weighting follows from equations (15)- (17). Following the convolution theorem, the one-dimensional filtration of each radiograph (equation (18)) is performed in the frequency domain [17]. First, the one-dimensional fast Fourier transform (FFT) of each row in the radiograph is calculated.…”
Section: Methodsmentioning
confidence: 99%
“…combination of weighted contributions of filtered projections from all rotation positions. Hence, implementation of equation 3 consists of two consecutive steps [17,18]: 1. Preprocessing: cosine weighting and convolution to obtain filtered projection ; 2.…”
Section: Prerequisitesmentioning
confidence: 99%
“…Since these early works, the field of GPU-accelerated CT reconstruction has exploded (Noel et al, 2010;Okitsu et al, 2010;Xu et al, 2010a;Vintache et al, 2010). Recent examples include several papers on using multiple GPUs to further accelerate reconstruction (Jang et al, 2009;Liria et al, 2012;Zhang et al, 2012;Zhu et al, 2012), including the incorporation of scatter correction into the reconstruction process (Sisniega et al, 2011), SART based reconstruction combined with motion compensation (Pang et al, 2011), CT reconstruction with OpenCL ) and an up-to-date and thorough comparison of different hardware implementations (CPU, GPU, FPGA and the Cell Broadband Architecture) of FBP (Scherl et al, 2012).…”
Section: Ctmentioning
confidence: 99%
“…The equation 16 using the Fourier transform, F , for finding the MTF given the point spread function (PSF) data is shown in Eq. (11). The solution for the MTF of the system is shown in Eqs.…”
Section: Frequency Responsementioning
confidence: 99%
“…The backprojection operation does not perform any filtering or weighting of the projection data. This work implemented the p-matrix voxel driven backprojection algorithm as described in Scherl et al, 11 Wiesent et al, 12 and Galigekere et al 13 The Hadamard product "°" of the weighting volume, i W , and the constraining image, i C , generates raw 4-D time frame, i 4D , data, which can be further processed. The postprocessing includes corrections for vessel overlap in a projection, which causes a reconstruction artifact, higher than actual values during overlap periods, in the TACs of 4-D DSA.…”
Section: Introductionmentioning
confidence: 99%