2019
DOI: 10.1016/j.sajb.2019.08.055
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of some biological activities of the tubers of Corydalis solida (L.) Clairv. ssp. incisa Liéden growing in Turkey

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 12 publications
0
2
0
Order By: Relevance
“…LC-QTOF-MS analysis parameters of G coded sub-fractions [Column: TC-C18 170Å (4.6 mm × 150 mm × 5 μm; Column oven: 30 °C; Injection amount: 10 μl; Analysis time: 82 min; Mobile phase A: 0.1% acetic acid (v/v); Mobile phase B: Acetonitrile; Flow: 0.65 ml/ min; Flow program; 0 min-5% B, 4 min-5% B, 12 min-10% B, 15 min-10% B, 28 min-20% B, 48 min-40% B, 60 min-60% B, 65 min-70% B; 66 min-90% B; 72 min-90% B; 72.10 min-5% B; UV: 260 nm (20 Hz); Ionization mode: Negative; Drying gas temperature: 200 °C; Drying gas flow, nitrogen: 14 L/min; Nebulizer: 40 psi; Sheath gas temperature: 375 °C; Sheat gas flow, nitrogen: 11 L/min; Capillary voltage: 1100 V; Nozzle voltage: 2000 V; Mass reading range: 30-1700 amu; Reference ions: 980.0147, 1033.9881. Data evaluation and identification were done using Agilent Masshunter Software and Metlin Metabolite database and m/z values, fragment ions and retention time (if standards are available) (Kılıc et al, 2019).…”
Section: Characterization Of Sub-fractions By Lc-qtof-ms Analysismentioning
confidence: 99%
“…LC-QTOF-MS analysis parameters of G coded sub-fractions [Column: TC-C18 170Å (4.6 mm × 150 mm × 5 μm; Column oven: 30 °C; Injection amount: 10 μl; Analysis time: 82 min; Mobile phase A: 0.1% acetic acid (v/v); Mobile phase B: Acetonitrile; Flow: 0.65 ml/ min; Flow program; 0 min-5% B, 4 min-5% B, 12 min-10% B, 15 min-10% B, 28 min-20% B, 48 min-40% B, 60 min-60% B, 65 min-70% B; 66 min-90% B; 72 min-90% B; 72.10 min-5% B; UV: 260 nm (20 Hz); Ionization mode: Negative; Drying gas temperature: 200 °C; Drying gas flow, nitrogen: 14 L/min; Nebulizer: 40 psi; Sheath gas temperature: 375 °C; Sheat gas flow, nitrogen: 11 L/min; Capillary voltage: 1100 V; Nozzle voltage: 2000 V; Mass reading range: 30-1700 amu; Reference ions: 980.0147, 1033.9881. Data evaluation and identification were done using Agilent Masshunter Software and Metlin Metabolite database and m/z values, fragment ions and retention time (if standards are available) (Kılıc et al, 2019).…”
Section: Characterization Of Sub-fractions By Lc-qtof-ms Analysismentioning
confidence: 99%
“…In recent studies, it has been reported that some Corydalis species can be used against Alzheimer's disease. It has been proven that isoquinoline alkaloids isolated from various Corydalis species have acetylcholinesterase inhibitory effects [6][7][8][9].…”
Section: Introductionmentioning
confidence: 99%