2022
DOI: 10.1016/j.aca.2022.339724
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of solution anode glow discharge as a vapor generator in ICP-OES procedures: Application to highly sensitive determination of Cd and Hg

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 21 publications
(10 citation statements)
references
References 39 publications
0
10
0
Order By: Relevance
“…Hg is a global health threat and causes impairments in the human nervous system (Karthikeyan et al, 2021). Many terrible diseases such as Minamata and Parkinson's disease are related to the overexposure and excessive accumulation of mercury (Cai and Wang, 2022). The International Codex Alimentarius Commission stipulates that the maximum residue limit for Cd in vegetables is 0.1 mg kg −1 , and China sets the limit for Hg at 0.01 mg kg −1 .…”
Section: Introductionmentioning
confidence: 99%
“…Hg is a global health threat and causes impairments in the human nervous system (Karthikeyan et al, 2021). Many terrible diseases such as Minamata and Parkinson's disease are related to the overexposure and excessive accumulation of mercury (Cai and Wang, 2022). The International Codex Alimentarius Commission stipulates that the maximum residue limit for Cd in vegetables is 0.1 mg kg −1 , and China sets the limit for Hg at 0.01 mg kg −1 .…”
Section: Introductionmentioning
confidence: 99%
“…As shown in Table 1, the DL of this work was reduced by tens to hundreds of times compared with those of owing liquid anode (FLA)-APGD and ICP-AES methods without chemical vapor generation. The DL obtained by this proposed method was comparable to that of SAGD-ICP-OES, SCGD-ICP-AES and CVG-ICP-AES, [36][37][38][39] but the inherent defects of these instruments such as high energy consumption and large size still limit the development of their portability. In addition, the DL of SCGD microplasma induced vapor generation (MIVG)-APGD-OES was at the equivalent level of this work.…”
Section: Analytical Performancementioning
confidence: 71%
“…The recovery of a Ag spike was 102%. Cai and Wang 79 took a different approach with the aim of eliminating the need for CVG reagents and pneumatic nebulisation. They used a solution anode GD not as an emission source but as a vapour generator for the determination of Cd and Hg by ICP-AES.…”
Section: Analysis Of Soils Plants and Related Materialsmentioning
confidence: 99%
“…Microplasmas or discharges can also be used to produce volatile metal compounds. An anodic GD was developed 79 for the CVG of Cd and Hg in waters and sediment digests prior to ICP-AES detection. The LODs of 0.3 (Cd) and 0.2 (Hg) mg L −1 were improvements over those achievable with pneumatic nebulisation.…”
Section: Atomic Absorption Spectrometrymentioning
confidence: 99%