2017
DOI: 10.1016/j.chroma.2016.11.056
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of size exclusion chromatography columns packed with sub-3 μm particles for the analysis of biopharmaceutical proteins

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
50
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
4
3

Relationship

2
5

Authors

Journals

citations
Cited by 67 publications
(53 citation statements)
references
References 26 publications
3
50
0
Order By: Relevance
“…Size-exclusion chromatography (SEC) is a traditional technique widely used for protein characterization and quality control [53]. The main application of SEC is the quantitative determination of protein aggregates.…”
Section: Size-exclusion Chromatographymentioning
confidence: 99%
See 1 more Smart Citation
“…Size-exclusion chromatography (SEC) is a traditional technique widely used for protein characterization and quality control [53]. The main application of SEC is the quantitative determination of protein aggregates.…”
Section: Size-exclusion Chromatographymentioning
confidence: 99%
“…SEC separation should be performed in conditions as inert as possible. Recently, SEC columns packed with sub-3 m particles have been introduced, making possible to perform ultra-high performance size-exclusion (SE-UHPLC or UHP-SEC) separations within 5-10 min analysis time range [53,59,62]. UHP-SEC columns perform two or three times lower plate heights compared to conventional 5-10 m SEC packing.…”
Section: Size-exclusion Chromatographymentioning
confidence: 99%
“…The evaluation of SEC columns packed with sub‐3 and sub‐2 μm particles for the analysis of mAbs and ADCs was described by Fekete et al. showing that an additional gain in time can be achieved without compromising analysis time . The same group also reported the risk of forming on‐column aggregates when applying small‐particle columns under high‐pressure conditions .…”
Section: Native Lc Modesmentioning
confidence: 99%
“…Furthermore, it was demonstrated that a factor of 2 in analysis time could be gained when using 3 μm SEC resins instead of 5 μm particles, and optimizing the column length-to-particlediameter ratio, such that the column efficiency was maintained [31]. The evaluation of SEC columns packed with sub-3 and sub-2 μm particles for the analysis of mAbs and ADCs was described by Fekete et al showing that an additional gain in time can be achieved without compromising analysis time [32,33]. The same group also reported the risk of forming on-column aggregates when applying small-particle columns under high-pressure conditions [34].…”
Section: Aqueous Size-exclusion Chromatography For the Analysis Of Prmentioning
confidence: 99%
“…Fractions exhibiting antioxidant properties were confirmed by electrophoresis and mass spectrometric analysis to have a molecular mass below 3 kDa. It must be noted that the performance of an SE‐HPLC system in peptide isolation and purification, with concomitant determination of molecular weight, is affected by parameters such as the pore volume, nature of mobile phase, ionic strength, and type of the SEC solid phase matrix (Bouvier & Koza, ; Goyon et al, ). These parameters are essential to minimize unwanted hydrophobic peptide–peptide interactions, and peptide–solid phase interaction; which could potentially alter their molecular weight, yield, and biological properties (Irvine, ).…”
Section: Structure‐informed Separation Processesmentioning
confidence: 99%