Evaluation of silicon strip detectors in transmission mode for online beam monitoring in microbeam radiation therapy at the Australian Synchrotron

Abstract: Successful transition of synchrotron-based microbeam radiation therapy (MRT) from pre-clinical animal studies to human trials is dependent upon ensuring that there are sufficient and adequate measures in place for quality assurance purposes. Transmission detectors provide researchers and clinicians with a real-time quality assurance and beam-monitoring instrument to ensure safe and accurate dose delivery. In this work, the effect of transmission detectors of different thicknesses (10 and 375 µm) upon the photo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 38 publications
0
2
0
Order By: Relevance
“…However, the energy dependence of the combination of fibre-optic and OPD dosimeters are heavily dependent on the plastic scintillator material used (Archer et al 2018, Posar et al 2020, Large Posar et al 2021. Silicon strip detectors are an attractive solution for MRT dosimetry, with spatial resolution able to resolve individual microbeams and dosimetric response closely matching commercially available detectors (Lerch et al 2011, Wong et al 2011, Petasecca et al 2012, Davis et al 2022. A promising solution for MRT dosimetry is also represented by single-crystal diamond dosimeters such as the commercially available PTW microDiamond 60019, which has demonstrated exceptional performances for dosimetry of synchrotron microbeams.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…However, the energy dependence of the combination of fibre-optic and OPD dosimeters are heavily dependent on the plastic scintillator material used (Archer et al 2018, Posar et al 2020, Large Posar et al 2021. Silicon strip detectors are an attractive solution for MRT dosimetry, with spatial resolution able to resolve individual microbeams and dosimetric response closely matching commercially available detectors (Lerch et al 2011, Wong et al 2011, Petasecca et al 2012, Davis et al 2022. A promising solution for MRT dosimetry is also represented by single-crystal diamond dosimeters such as the commercially available PTW microDiamond 60019, which has demonstrated exceptional performances for dosimetry of synchrotron microbeams.…”
Section: Introductionmentioning
confidence: 99%
“…The experimental dosimetric characterisations summarised in this work are performed on an innovative a-Si:H device structure based on a selection of CSC deposited on an intrinsic amorphous substrate (Menichelli et al 2021). The dosimetry protocols adopted are the ones developed for synchrotron-based radiotherapy and MRT as outlined in the works of Prezado et al (2011) and Davis et al (2022).…”